Non-invasive quantification of pressure drops in stenotic intracranial vessels: using deep learning-enhanced 4D flow MRI to characterize the regional haemodynamics of the pulsing brain

Stenosis of major intracranial arteries is a significant cause of stroke, with assessment of trans-stenotic pressure drops being a key marker of functional stenosis severity. Non-invasive methods for quantifying intracranial pressure changes are hence crucial; however, the narrow and tortuous cerebrovascular network poses challenges to traditional assessment methods such as transcranial Doppler. This study investigates the use of novel deep learning-enhanced super-resolution (SR) four-dimensional (4D) flow magnetic resonance imaging (MRI) in combination with a physics-informed virtual work-energy relative pressure technique to quantify pressure drops across stenotic intracranial arteries. Performance was validated in intracranial-mimicking <i>in vitro</i> experiments using pulsatile flow before being transferred into an <i>in vivo</i> cohort of patients with intracranial atherosclerotic disease. Conversion into sub-millimetre SR imaging significantly improved the accuracy of regional relative pressure estimations in the pulsing brain arteries, mitigating biases observed at >1 mm resolution imaging, and agreeing strongly with reference catheter-based invasive measurements across both moderate and severe stenoses. The <i>in vivo</i> analysis also revealed a significant increase in pressure drops when converting into sub-millimetre SR data, underlining the importance of apparent image resolution in a clinical setting. The results highlight the potential of SR 4D flow MRI for non-invasive quantification of cerebrovascular pressure changes in pulsing intracranial arteries across stenotic vessel segments.

Authors

Institutions

Publication Details

Journal
Interface Focus
Published
2025-04-04
DOI
https://doi.org/10.1098/rsfs.2024.0040
Citations
3
Primary Topic
Cerebrovascular and Carotid Artery Diseases
Type
article
Field-Weighted Citation Impact
4.56

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-invasive quantification of pressure drops in stenotic intracranial vessels: using deep learning-enhanced 4D flow MRI to characterize the regional haemodynamics of the pulsing brain

Sameer A. Ansari, Alireza Vali, Michael Markl, Maria Aristova et al.
3 citations
Interface Focus
Cerebrovascular and Carotid Artery Diseases
4.56
article

Non-invasive quantification of pressure drops in stenotic intracranial vessels: using deep learning-enhanced 4D flow MRI to characterize the regional haemodynamics of the pulsing brain

Sameer A. Ansari, Alireza Vali, Michael Markl, Maria Aristova, R Abdalla, Susanne Schnell, Patrick Winter, David Marlevi, Ali El Ahmar
article en
3 citations

Abstract

Stenosis of major intracranial arteries is a significant cause of stroke, with assessment of trans-stenotic pressure drops being a key marker of functional stenosis severity. Non-invasive methods for quantifying intracranial pressure changes are hence crucial; however, the narrow and tortuous cerebrovascular network poses challenges to traditional assessment methods such as transcranial Doppler. This study investigates the use of novel deep learning-enhanced super-resolution (SR) four-dimensional (4D) flow magnetic resonance imaging (MRI) in combination with a physics-informed virtual work-energy relative pressure technique to quantify pressure drops across stenotic intracranial arteries. Performance was validated in intracranial-mimicking <i>in vitro</i> experiments using pulsatile flow before being transferred into an <i>in vivo</i> cohort of patients with intracranial atherosclerotic disease. Conversion into sub-millimetre SR imaging significantly improved the accuracy of regional relative pressure estimations in the pulsing brain arteries, mitigating biases observed at >1 mm resolution imaging, and agreeing strongly with reference catheter-based invasive measurements across both moderate and severe stenoses. The <i>in vivo</i> analysis also revealed a significant increase in pressure drops when converting into sub-millimetre SR data, underlining the importance of apparent image resolution in a clinical setting. The results highlight the potential of SR 4D flow MRI for non-invasive quantification of cerebrovascular pressure changes in pulsing intracranial arteries across stenotic vessel segments.

Interface FocusVol. 15(1)
Qualcomm (United Kingdom) (GB), Karolinska Institutet (SE), Universität Greifswald (DE), Neurological Surgery (US), Massachusetts Institute of Technology (US)
Deutsche Forschungsgemeinschaft, European Research Council, National Heart, Lung, and Blood Institute, National Institute of Neurological Disorders and Stroke
Openalex Percentile: Top 6%
Cerebrovascular and Carotid Artery Diseases
4.56
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.