Correcting for sub-resolution tissue motion in localization optoacoustic tomography

Localization optoacoustic tomography (LOT) has recently been suggested for enhancing spatial resolution in optoacoustic imaging beyond the acoustic diffraction barrier and further enabling measuring blood flow velocity. LOT relies on tracking highly absorbing particles in a sequence of images acquired following intravenous injection. Much like for other high-resolution imaging methods, the achievable resolution <i>in vivo</i> is afflicted by physiological motion. Inter-frame displacements further hamper particle tracking and accurate velocity measurements. Herein, we propose a geometric-transformation-based approach to align motion-affected frames to a reference frame. This is achieved with a singular value decomposition (SVD) clutter filter, clustering the acquired sequence into low-order singular vectors representing blood-vessel background and high-order singular values related to flowing particles. Motion estimation is then performed in the background sequence, and localization and tracking are subsequently done in the flowing-particle sequence after motion correction. The enhanced performance achieved with the suggested approach is demonstrated in phantom experiments and LOT images of the mouse brain.

Authors

Institutions

Publication Details

Journal
Optics Letters
Published
2025-04-04
DOI
https://doi.org/10.1364/ol.557507
Citations
1
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Correcting for sub-resolution tissue motion in localization optoacoustic tomography

Daniil Nozdriukhin, Xosé Luís Deán‐Ben, Jinhua Zhao, Daniel Razansky
1 citations
Optics Letters
Photoacoustic and Ultrasonic Imaging
0.67
article

Correcting for sub-resolution tissue motion in localization optoacoustic tomography

Daniil Nozdriukhin, Xosé Luís Deán‐Ben, Jinhua Zhao, Daniel Razansky
article en
1 citations

Abstract

Localization optoacoustic tomography (LOT) has recently been suggested for enhancing spatial resolution in optoacoustic imaging beyond the acoustic diffraction barrier and further enabling measuring blood flow velocity. LOT relies on tracking highly absorbing particles in a sequence of images acquired following intravenous injection. Much like for other high-resolution imaging methods, the achievable resolution <i>in vivo</i> is afflicted by physiological motion. Inter-frame displacements further hamper particle tracking and accurate velocity measurements. Herein, we propose a geometric-transformation-based approach to align motion-affected frames to a reference frame. This is achieved with a singular value decomposition (SVD) clutter filter, clustering the acquired sequence into low-order singular vectors representing blood-vessel background and high-order singular values related to flowing particles. Motion estimation is then performed in the background sequence, and localization and tracking are subsequently done in the flowing-particle sequence after motion correction. The enhanced performance achieved with the suggested approach is demonstrated in phantom experiments and LOT images of the mouse brain.

Optics LettersVol. 50(9)
University of Zurich (CH), Institute for Biomedical Engineering (CH)
Openalex Percentile: Top 33%
Photoacoustic and Ultrasonic Imaging
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.