Analytical Method Development and Validation of Remdesivir and Griseofulvin in API and its Dosage Form by RP-HPLC

Background: The suggested approach is appropriate for the quantitative measurement of Remdesivir and Griseofulvin in a variety of pharmaceutical dosage forms, according to experimental findings. The technique offers excellent repeatability, linearity, and sensitivity. Remdesivir and Griseofulvin were estimated using RP-HPLC. Objective: The objective was to accomplish method development and validation of Remdesivir and Griseofulvin. Materials and Methods: The mobile phase was adjusted and consisted of acetonitrile and phosphate buffer mixed in a 70:30% v/v ratio. 4.6 was the pH of the phosphate buffer. An X Terra Symmetry C18 (4.6 x 250mm, 5µm) column is used as the stationary phase. For the detection, a UV detector tuned to 221 nm was employed. Chromatography of the solutions was performed at a constant flow rate of 1.0 ml/min. Many trials have been carried out to obtain an optimized chromatogram. Results: Remdesivir and Griseofulvin were reported to have linearity ranges of 25-125 µg/ml. There was no increase in the linear regression coefficient above 0.999. The accuracy and precision of the procedure are indicated by the percentage RSD readings being less than 2%. The percentage recovery for Griseofulvin and Remdesivir ranges from 97 to 100%. It was discovered that LOD and LOQ were inside the range. Conclusion: The suggested technique for figuring out how much Remdesivir and Griseofulvin are in a formulation is exact, easy to use, and accurate. A high recovery rate indicates that the formulation's excipients are not interfering with the process. Therefore, the technique may be helpful for routinely checking the quality of these medications.

Authors

Publication Details

Journal
International Journal of Drug Delivery Technology
Published
2025-03-25
DOI
https://doi.org/10.25258/ijddt.15.1.19
Citations
1
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.75
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analytical Method Development and Validation of Remdesivir and Griseofulvin in API and its Dosage Form by RP-HPLC

Ravi Kumar Konda, K. M. Pravalika, G Haritha, Rakam Gopi Krishna et al.
1 citations
International Journal of Drug Delivery Technology
Analytical Methods in Pharmaceuticals
0.75
article

Analytical Method Development and Validation of Remdesivir and Griseofulvin in API and its Dosage Form by RP-HPLC

Ravi Kumar Konda, K. M. Pravalika, G Haritha, Rakam Gopi Krishna, V.A.N.V. Harita
article en
1 citations

Abstract

Background: The suggested approach is appropriate for the quantitative measurement of Remdesivir and Griseofulvin in a variety of pharmaceutical dosage forms, according to experimental findings. The technique offers excellent repeatability, linearity, and sensitivity. Remdesivir and Griseofulvin were estimated using RP-HPLC. Objective: The objective was to accomplish method development and validation of Remdesivir and Griseofulvin. Materials and Methods: The mobile phase was adjusted and consisted of acetonitrile and phosphate buffer mixed in a 70:30% v/v ratio. 4.6 was the pH of the phosphate buffer. An X Terra Symmetry C18 (4.6 x 250mm, 5µm) column is used as the stationary phase. For the detection, a UV detector tuned to 221 nm was employed. Chromatography of the solutions was performed at a constant flow rate of 1.0 ml/min. Many trials have been carried out to obtain an optimized chromatogram. Results: Remdesivir and Griseofulvin were reported to have linearity ranges of 25-125 µg/ml. There was no increase in the linear regression coefficient above 0.999. The accuracy and precision of the procedure are indicated by the percentage RSD readings being less than 2%. The percentage recovery for Griseofulvin and Remdesivir ranges from 97 to 100%. It was discovered that LOD and LOQ were inside the range. Conclusion: The suggested technique for figuring out how much Remdesivir and Griseofulvin are in a formulation is exact, easy to use, and accurate. A high recovery rate indicates that the formulation's excipients are not interfering with the process. Therefore, the technique may be helpful for routinely checking the quality of these medications.

International Journal of Drug Delivery TechnologyVol. 15(01)
Openalex Percentile: Top 34%
Analytical Methods in Pharmaceuticals
0.75
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analytical Method Development and Validation of Remdesivir and Griseofulvin in API and its Dosage Form by RP-HPLC — Ravi Kumar Konda, K. M. Pravalika, et al. · International Journal of Drug Delivery Technology (2025) | TGRS Research Map | TGRS