Full energy peak efficiency of a clover detector in direct and add-back modes at different source to detector distances: a comparative study

A comparative study of the effect of true coincidence summing (TCS) on the full-energy peak efficiency calibration of a clover HPGe detector, for direct and add-back modes of operation, has been done at different source-to-detector distances (d). The detector response was simulated using the Geant4 toolkit. The TCS correction factors determined by both experimental and analytical methods have been found to agree well with each other. The clover detector in add-back mode exhibits larger summing corrections than the direct mode for the same distance d. The distance d below which the summing correction becomes significant for the add-back mode of measurement is found to be higher than the corresponding distance for the direct mode of measurement for a clover detector.

Authors

Institutions

Publication Details

Journal
Journal of Radioanalytical and Nuclear Chemistry
Published
2025-04-02
DOI
https://doi.org/10.1007/s10967-025-10081-7
Citations
1
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
1.88
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Full energy peak efficiency of a clover detector in direct and add-back modes at different source to detector distances: a comparative study

Saikat Bhattacharjee, A. Mukherjee, M. Shareef, Munmun Twisha et al.
1 citations
Journal of Radioanalytical and Nuclear Chemistry
Radiation Detection and Scintillator Technologies
1.88
article

Full energy peak efficiency of a clover detector in direct and add-back modes at different source to detector distances: a comparative study

Saikat Bhattacharjee, A. Mukherjee, M. Shareef, Munmun Twisha, Ashish Gupta
article en
1 citations

Abstract

A comparative study of the effect of true coincidence summing (TCS) on the full-energy peak efficiency calibration of a clover HPGe detector, for direct and add-back modes of operation, has been done at different source-to-detector distances (d). The detector response was simulated using the Geant4 toolkit. The TCS correction factors determined by both experimental and analytical methods have been found to agree well with each other. The clover detector in add-back mode exhibits larger summing corrections than the direct mode for the same distance d. The distance d below which the summing correction becomes significant for the add-back mode of measurement is found to be higher than the corresponding distance for the direct mode of measurement for a clover detector.

Journal of Radioanalytical and Nuclear ChemistryVol. 334(5)
Saha Institute of Nuclear Physics (IN), Homi Bhabha National Institute (IN)
Affordable and clean energy
Openalex Percentile: Top 19%
Radiation Detection and Scintillator Technologies
1.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Full energy peak efficiency of a clover detector in direct and add-back modes at different source to detector distances: a comparative study — Saikat Bhattacharjee, A. Mukherjee, et al. · Journal of Radioanalytical and Nuclear Chemistry (2025) | TGRS Research Map | TGRS