Six Sigma-Based Frequency Response Analysis for Power Transformer Winding Deformation

Winding deformities in distribution transformers pose significant risks to operational reliability and system safety. Frequency response analysis (FRA) is a well-established technique for identifying mechanical faults; however, its diagnostic reliability is hindered by subjectivity in interpreting response signatures. This study proposes a novel diagnostic technique, termed FRA6σ, which integrates Six Sigma (6σ) statistical tools with FRA to enable objective fault detection. The methodology employs control charts (X¯ chart, R¯-chart) to monitor deviations from baseline signatures and utilizes process capability indices (Cp and Cpk) to quantify the severity of deviations. Three transformer cases were evaluated across five defined frequency regions (10 Hz to 2 MHz), each associated with distinct physical fault types. The FRA6σ approach successfully identified early-stage faults across all cases. In one instance, axial and radial winding deformation was detected with a Cp of 1.0 and corresponding range chart violations, preceding any visible damage. Another case revealed inter-turn insulation degradation in the 100 kHz–1 MHz band with Cpk values below 0.9, prompting immediate intervention. Compared to traditional FRA interpretation, the proposed method improved diagnostic sensitivity by 31.25% and enabled fault detection earlier based on retrospective physical inspection benchmarks. The integration of Six Sigma with FRA provides a structured, quantifiable, and repeatable approach to transformer fault diagnostics. FRA6σ enhances early detection of winding deformities and dielectric issues, offering a robust alternative to subjective analysis and supporting predictive maintenance strategies in power systems.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-04-03
DOI
https://doi.org/10.3390/app15073951
Citations
2
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
1.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Six Sigma-Based Frequency Response Analysis for Power Transformer Winding Deformation

Bonginkosi Allen Thango
2 citations
Applied Sciences
Power Transformer Diagnostics and Insulation
1.46
article

Six Sigma-Based Frequency Response Analysis for Power Transformer Winding Deformation

Bonginkosi Allen Thango
article en
2 citations

Abstract

Winding deformities in distribution transformers pose significant risks to operational reliability and system safety. Frequency response analysis (FRA) is a well-established technique for identifying mechanical faults; however, its diagnostic reliability is hindered by subjectivity in interpreting response signatures. This study proposes a novel diagnostic technique, termed FRA6σ, which integrates Six Sigma (6σ) statistical tools with FRA to enable objective fault detection. The methodology employs control charts (X¯ chart, R¯-chart) to monitor deviations from baseline signatures and utilizes process capability indices (Cp and Cpk) to quantify the severity of deviations. Three transformer cases were evaluated across five defined frequency regions (10 Hz to 2 MHz), each associated with distinct physical fault types. The FRA6σ approach successfully identified early-stage faults across all cases. In one instance, axial and radial winding deformation was detected with a Cp of 1.0 and corresponding range chart violations, preceding any visible damage. Another case revealed inter-turn insulation degradation in the 100 kHz–1 MHz band with Cpk values below 0.9, prompting immediate intervention. Compared to traditional FRA interpretation, the proposed method improved diagnostic sensitivity by 31.25% and enabled fault detection earlier based on retrospective physical inspection benchmarks. The integration of Six Sigma with FRA provides a structured, quantifiable, and repeatable approach to transformer fault diagnostics. FRA6σ enhances early detection of winding deformities and dielectric issues, offering a robust alternative to subjective analysis and supporting predictive maintenance strategies in power systems.

Applied SciencesVol. 15(7)
University of Johannesburg (ZA)
Openalex Percentile: Top 18%
Power Transformer Diagnostics and Insulation
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.