DEVELOPMENT AND TESTING OF A SYSTEM DIAGNOSTIC BASED ON A TRIPLE LANGMUIR PROBE IN A PLASMA-BEAM INSTALLATION

The paper presents the development of a triple probe consisting of three tungsten electrodes with a diameter of 1 mm, intended for applications on a plasma beam installation (PBI). The appropriate measuring equipment and electrical wiring diagram have been selected. The probe has successfully passed the commissioning tests, during which key factors were identified that are important for accurate interpretation of the results and integration into the diagnostic system of the PBI. Experimental measurements of plasma parameters using a triple probe showed comparable results with a single probe: the electron temperature was 7 eV, and the plasma concentration was – 10¹⁶ m⁻³. The experimental results obtained confirm the correct operation of the developed probe and its use in experiments due to the simplicity of data processing compared with other types of probes.

Authors

Institutions

Publication Details

Journal
NNC RK Bulletin
Published
2025-04-01
DOI
https://doi.org/10.52676/1729-7885-2025-1-21-27
Primary Topic
Plasma Diagnostics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DEVELOPMENT AND TESTING OF A SYSTEM DIAGNOSTIC BASED ON A TRIPLE LANGMUIR PROBE IN A PLASMA-BEAM INSTALLATION

А. Zh. Miniyazov, Т. Р. Туленбергенов, Gainiya Zhanbolatova, И. А. Соколов et al.
NNC RK Bulletin
Plasma Diagnostics and Applications
article

DEVELOPMENT AND TESTING OF A SYSTEM DIAGNOSTIC BASED ON A TRIPLE LANGMUIR PROBE IN A PLASMA-BEAM INSTALLATION

А. Zh. Miniyazov, Т. Р. Туленбергенов, Gainiya Zhanbolatova, И. А. Соколов, A. Zh. Kaiуrbekova
article en

Abstract

The paper presents the development of a triple probe consisting of three tungsten electrodes with a diameter of 1 mm, intended for applications on a plasma beam installation (PBI). The appropriate measuring equipment and electrical wiring diagram have been selected. The probe has successfully passed the commissioning tests, during which key factors were identified that are important for accurate interpretation of the results and integration into the diagnostic system of the PBI. Experimental measurements of plasma parameters using a triple probe showed comparable results with a single probe: the electron temperature was 7 eV, and the plasma concentration was – 10¹⁶ m⁻³. The experimental results obtained confirm the correct operation of the developed probe and its use in experiments due to the simplicity of data processing compared with other types of probes.

NNC RK Bulletin(1)
Institute of Atomic Energy (PL), Shakarim University (KZ)
Openalex Percentile: Top 95%
Plasma Diagnostics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.