Aerosol dispersion and energy consumption in a mechanically heated and cooled multi-chair dental office with windows routinely opened

Natural ventilation via open windows is a common practice widely applied to dilute aerosols in dental offices for all year around in China, which, however, would modifies air distribution and leads to extra energy consumption for cooling and heating. This study intends to evaluate aerosol removal efficiency and energy consumption in a multi-chair dental office with both mechanical ventilation (MV) and natural ventilation (NV), namely, mixed-mode ventilation (MMV). It numerically investigates the effect of ventilation mode and environmental condition on indoor aerosol distribution and fallow time (FT) duration, as well as energy consumption. The results show that introducing fresh air via open windows in such a mechanically ventilated space results in enhanced airflow mixing and particle dispersion. Compared to six air changes per hour (ACH) MV mode, MMV mode with less than 4 ACH NV does not ensure a reduction in suspended particle count indoors. When NV rate reaches 6 ACH, all compartments show an average reduction of 64.6% in particle counts. However, energy consumption for MMV mode with 6 ACH NV is 3.5 times higher during heating seasons and 2.2 times higher during cooling seasons compared to 6 ACH MV mode. Compared to MV mode with recommended FT of 18–21 min between appointments, MMV mode with 4–6 ACH NV has the required FT of 14–16 min. This study is intended to provide references for clinic managers to balance air quality improvements with energy consumption, thereby achieving a sustainable indoor environment and optimizing operational costs in multi-chair dental offices.

Authors

Institutions

Publication Details

Journal
Physics of Fluids
Published
2025-04-01
DOI
https://doi.org/10.1063/5.0264026
Citations
1
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
1.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Aerosol dispersion and energy consumption in a mechanically heated and cooled multi-chair dental office with windows routinely opened

Jie Zong, Zhengtao Ai, Yan Hu, Yufan Chang
1 citations
Physics of Fluids
Infection Control and Ventilation
1.52
article

Aerosol dispersion and energy consumption in a mechanically heated and cooled multi-chair dental office with windows routinely opened

Jie Zong, Zhengtao Ai, Yan Hu, Yufan Chang
article en
1 citations

Abstract

Natural ventilation via open windows is a common practice widely applied to dilute aerosols in dental offices for all year around in China, which, however, would modifies air distribution and leads to extra energy consumption for cooling and heating. This study intends to evaluate aerosol removal efficiency and energy consumption in a multi-chair dental office with both mechanical ventilation (MV) and natural ventilation (NV), namely, mixed-mode ventilation (MMV). It numerically investigates the effect of ventilation mode and environmental condition on indoor aerosol distribution and fallow time (FT) duration, as well as energy consumption. The results show that introducing fresh air via open windows in such a mechanically ventilated space results in enhanced airflow mixing and particle dispersion. Compared to six air changes per hour (ACH) MV mode, MMV mode with less than 4 ACH NV does not ensure a reduction in suspended particle count indoors. When NV rate reaches 6 ACH, all compartments show an average reduction of 64.6% in particle counts. However, energy consumption for MMV mode with 6 ACH NV is 3.5 times higher during heating seasons and 2.2 times higher during cooling seasons compared to 6 ACH MV mode. Compared to MV mode with recommended FT of 18–21 min between appointments, MMV mode with 4–6 ACH NV has the required FT of 14–16 min. This study is intended to provide references for clinic managers to balance air quality improvements with energy consumption, thereby achieving a sustainable indoor environment and optimizing operational costs in multi-chair dental offices.

Physics of FluidsVol. 37(4)
Hunan University (CN)
Natural Science Foundation of Hunan Province, Fundamental Research Funds for the Central Universities
Openalex Percentile: Top 20%
Infection Control and Ventilation
1.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Aerosol dispersion and energy consumption in a mechanically heated and cooled multi-chair dental office with windows routinely opened — Jie Zong, Zhengtao Ai, et al. · Physics of Fluids (2025) | TGRS Research Map | TGRS