First experimental test of a coded-mask gamma camera for proton therapy monitoring

<i>Objective.</i>The objective of the presented study was to evaluate the feasibility of a coded-mask (CM) gamma camera for real-time range verification in proton therapy, addressing the need for a precise and efficient method of treatment monitoring.<i>Approach.</i>A CM gamma camera prototype was tested in clinical conditions. The setup incorporated a scintillator-based detection system and a structured tungsten collimator. The experiment consisted of the irradiation of PMMA phantom with proton beams of energies ranging from 70.51 to 108.15 MeV. Experimental data were benchmarked against Monte Carlo simulations. The distal falloff position (DFP) was determined for both experimental data and simulations.<i>Main results.</i>The tested CM camera achieved a statistical precision of DFP determination of 1.7 mm for 10<sup>8</sup>protons, which is consistent with simulation predictions, despite hardware limitations such as non-functional detector pixels. Simulations indicated that a fully operational setup would further improve the performance of the detector. The system demonstrated rate capability sufficient for clinical proton beam intensities and maintained performance without significant dead time.<i>Significance.</i>This study validates the potential of the CM gamma camera for real-time proton therapy monitoring. The technology promises to enhance treatment accuracy and patient safety, offering a competitive alternative to existing approaches such as single-slit and multi-slit systems.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-04-04
DOI
https://doi.org/10.1088/1361-6560/adc96b
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

First experimental test of a coded-mask gamma camera for proton therapy monitoring

Stephan Brons, Ronja Hetzel, Vitalii Urbanevych, Katarzyna Rusiecka et al.
Physics in Medicine and Biology
Radiation Therapy and Dosimetry
article

First experimental test of a coded-mask gamma camera for proton therapy monitoring

Stephan Brons, Ronja Hetzel, Vitalii Urbanevych, Katarzyna Rusiecka, A. Stahl, Ming-Liang Wong, J. Röser, Mikołaj Dubiel, M. Rafecas, Lara Mielke, Monika Kercz, Gabriel Ostrzołek, Magdalena Kołodziej, A. Wrońska, Jonas Kasper, Alexander Fenger, George N. Farah, Barbara Kołodziej
article en

Abstract

<i>Objective.</i>The objective of the presented study was to evaluate the feasibility of a coded-mask (CM) gamma camera for real-time range verification in proton therapy, addressing the need for a precise and efficient method of treatment monitoring.<i>Approach.</i>A CM gamma camera prototype was tested in clinical conditions. The setup incorporated a scintillator-based detection system and a structured tungsten collimator. The experiment consisted of the irradiation of PMMA phantom with proton beams of energies ranging from 70.51 to 108.15 MeV. Experimental data were benchmarked against Monte Carlo simulations. The distal falloff position (DFP) was determined for both experimental data and simulations.<i>Main results.</i>The tested CM camera achieved a statistical precision of DFP determination of 1.7 mm for 10<sup>8</sup>protons, which is consistent with simulation predictions, despite hardware limitations such as non-functional detector pixels. Simulations indicated that a fully operational setup would further improve the performance of the detector. The system demonstrated rate capability sufficient for clinical proton beam intensities and maintained performance without significant dead time.<i>Significance.</i>This study validates the potential of the CM gamma camera for real-time proton therapy monitoring. The technology promises to enhance treatment accuracy and patient safety, offering a competitive alternative to existing approaches such as single-slit and multi-slit systems.

Physics in Medicine and BiologyVol. 70(11)
Jagiellonian University (PL), Heidelberg University (DE), University Hospital Heidelberg (DE), Institute of Physics (PL), Heidelberger Institut für Radioonkologie (DE), Nierenzentrum Heidelberg (DE), RWTH Aachen University (DE), University of Lübeck (DE)
Deutscher Akademischer Austauschdienst, Deutsche Forschungsgemeinschaft, Bundesministerium für Bildung und Forschung, Narodowe Centrum Nauki, Uniwersytet Jagielloński w Krakowie, Narodowa Agencja Wymiany Akademickiej
Openalex Percentile: Top 90%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.