Development of SPR biosensors for quantitative detection of SARS-CoV-2 via recombinase polymerase amplification

The rapid and accurate detection of SARS-CoV-2, the virus responsible for COVID-19, remains a critical priority in public health. Surface Plasmon Resonance (SPR) biosensors have emerged as a powerful tool for real-time, label-free, and highly sensitive detection of viral pathogens. The integration of Recombinase Polymerase Amplification (RPA) with SPR biosensors and Lateral Flow Assay (LFA) enables quantitative detection of SARS-CoV-2 with high specificity and efficiency. This study presents a promising alternative: a fast, sensitive, and specific RPA method combined with CRISPR-Cas12a (Clustered Regularly Iinterspaced Short Palindromic Repeats-Cas12a), which reduces false positives. Enhanced with lateral flow assays, fluorescence for qualitative detection, and SPR for quantitative analysis, this approach achieves a detection limit as low as one DNA copy per reaction. This innovative RPA-CRISPR/Cas12a technique offers a powerful tool for rapid, accurate, and accessible COVID-19 diagnosis, holding great potential for future clinical applications. According to the LFA test results, the Limit of Detection (LOD) for CRISPR-based detection of RPA products was 10³ copies per reaction. Fluorescence intensity detection results indicate that the fluorescence intensity difference is minimal above 10¹ copies per reaction, with an LOD of 10¹ copies per reaction. For SPR quantitative detection, when the flow rate was set to 30 μL/min, the injection of RPA products at different concentrations caused a corresponding change in the SPR angle. The detection results fit a linear model (R² = 0.923), demonstrating that the detection limit could reach 10¹ copies per reaction. This RPA-CRISPR/Cas12a technique offers a powerful tool for rapid, accurate, and accessible COVID-19 diagnosis, with significant potential for clinical applications.

Authors

Institutions

Publication Details

Published
2025-04-04
DOI
https://doi.org/10.1117/12.3056568
Citations
1
Primary Topic
SARS-CoV-2 detection and testing
Type
article
Field-Weighted Citation Impact
1.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of SPR biosensors for quantitative detection of SARS-CoV-2 via recombinase polymerase amplification

Ying-Hao Wang, Nan‐Fu Chiu, Ming-Jung Tai, Tien-Hsiung Ku
1 citations
SARS-CoV-2 detection and testing
1.40
article

Development of SPR biosensors for quantitative detection of SARS-CoV-2 via recombinase polymerase amplification

Ying-Hao Wang, Nan‐Fu Chiu, Ming-Jung Tai, Tien-Hsiung Ku
article en
1 citations

Abstract

The rapid and accurate detection of SARS-CoV-2, the virus responsible for COVID-19, remains a critical priority in public health. Surface Plasmon Resonance (SPR) biosensors have emerged as a powerful tool for real-time, label-free, and highly sensitive detection of viral pathogens. The integration of Recombinase Polymerase Amplification (RPA) with SPR biosensors and Lateral Flow Assay (LFA) enables quantitative detection of SARS-CoV-2 with high specificity and efficiency. This study presents a promising alternative: a fast, sensitive, and specific RPA method combined with CRISPR-Cas12a (Clustered Regularly Iinterspaced Short Palindromic Repeats-Cas12a), which reduces false positives. Enhanced with lateral flow assays, fluorescence for qualitative detection, and SPR for quantitative analysis, this approach achieves a detection limit as low as one DNA copy per reaction. This innovative RPA-CRISPR/Cas12a technique offers a powerful tool for rapid, accurate, and accessible COVID-19 diagnosis, holding great potential for future clinical applications. According to the LFA test results, the Limit of Detection (LOD) for CRISPR-based detection of RPA products was 10³ copies per reaction. Fluorescence intensity detection results indicate that the fluorescence intensity difference is minimal above 10¹ copies per reaction, with an LOD of 10¹ copies per reaction. For SPR quantitative detection, when the flow rate was set to 30 μL/min, the injection of RPA products at different concentrations caused a corresponding change in the SPR angle. The detection results fit a linear model (R² = 0.923), demonstrating that the detection limit could reach 10¹ copies per reaction. This RPA-CRISPR/Cas12a technique offers a powerful tool for rapid, accurate, and accessible COVID-19 diagnosis, with significant potential for clinical applications.

National Taiwan Normal University (TW), Changhua Christian Hospital (TW)
Openalex Percentile: Top 22%
SARS-CoV-2 detection and testing
1.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development of SPR biosensors for quantitative detection of SARS-CoV-2 via recombinase polymerase amplification — Ying-Hao Wang, Nan‐Fu Chiu, et al. · (2025) | TGRS Research Map | TGRS