Design and Properties of SQUID Sensors With Octagonal Double Transformer for Cryogenic Current Comparator

Superconducting quantum interference devices (SQUIDs) with large input inductance and octagonal double transformer were designed and fabricated using Nb/Al-AlO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">x</sub>/Nb Josephson junctions for cryogenic current comparator. A 30-turn input coil of 1.5 μH is coupled to a large octagonal transformer of 3.6 nH, the counterpart of transformer is a 1.5-turn coil of 3.0 nH coupled to a second-order gradiometric SQUID of 97 pH. The octagonal double transformer makes low-inductance SQUID easily match to the large-inductance input coil. A current sensitivity of 1.1 μA/Φ<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</sub>, a flux noise of 3.8 μΦ<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</sub>/√Hz at 4 kHz and 9.7 μΦ<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</sub>/√Hz at 1 Hz were achieved at 4.2 K. Another SQUID sensor with 10-turn input coil of 0.5 μH coupled to a large octagonal transformer of 6.0 nH, which is coupled to a first-order gradiometric SQUID of 580 pH, achieves a lower current sensitivity of 0.5 μA/Φ<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</sub> and a flux noise of 17 μΦ<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</sub>/√Hz at 4 kHz.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3557831
Citations
3
Primary Topic
Magnetic Field Sensors Techniques
Type
article
Field-Weighted Citation Impact
2.19

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Properties of SQUID Sensors With Octagonal Double Transformer for Cryogenic Current Comparator

Da Xu, Wenhui Cao, Kunli Zhou, Zhenyu Yang et al.
3 citations
IEEE Transactions on Instrumentation and Measurement
Magnetic Field Sensors Techniques
2.19
article

Design and Properties of SQUID Sensors With Octagonal Double Transformer for Cryogenic Current Comparator

Da Xu, Wenhui Cao, Kunli Zhou, Zhenyu Yang, Yunfeng Lu, Qing Chen, Wei Li, Jinjin Li, Zhong Qing, Jianting Zhao
article en
3 citations

Abstract

Superconducting quantum interference devices (SQUIDs) with large input inductance and octagonal double transformer were designed and fabricated using Nb/Al-AlO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">x</sub>/Nb Josephson junctions for cryogenic current comparator. A 30-turn input coil of 1.5 μH is coupled to a large octagonal transformer of 3.6 nH, the counterpart of transformer is a 1.5-turn coil of 3.0 nH coupled to a second-order gradiometric SQUID of 97 pH. The octagonal double transformer makes low-inductance SQUID easily match to the large-inductance input coil. A current sensitivity of 1.1 μA/Φ<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</sub>, a flux noise of 3.8 μΦ<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</sub>/√Hz at 4 kHz and 9.7 μΦ<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</sub>/√Hz at 1 Hz were achieved at 4.2 K. Another SQUID sensor with 10-turn input coil of 0.5 μH coupled to a large octagonal transformer of 6.0 nH, which is coupled to a first-order gradiometric SQUID of 580 pH, achieves a lower current sensitivity of 0.5 μA/Φ<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</sub> and a flux noise of 17 μΦ<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</sub>/√Hz at 4 kHz.

IEEE Transactions on Instrumentation and MeasurementVol. 74
National Institute of Metrology (CN)
National Key Research and Development Program of China
Affordable and clean energy
Openalex Percentile: Top 13%
Magnetic Field Sensors Techniques
2.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.