Laser Scanning System for Hydrophilicity Mapping on Curved Surfaces

Contact angle measurement is the most common technique for examining surface hydrophilicity. This technique usually involves a camera to capture the side view of a droplet. However, it often overlooks the distribution of hydrophilicity over the entire sample surface. In this study, a novel laser scanning technique was developed to obtain hydrophilicity maps of a curved sample surface with a maximum area of 175 mm × 250 mm. Moreover, a rotational tracking mechanism enabled the system to measure the curved surface with a tilt angle range of ±15°. The experiments yielded hydrophilicity maps of a polyimide film and glass slides. The results indicated that the developed laser scanning system was able to accurately determine the quantitative contact angle, height, and tilt angle images on the curved sample surface.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3557818
Citations
1
Primary Topic
Surface Roughness and Optical Measurements
Type
article
Field-Weighted Citation Impact
1.33
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Laser Scanning System for Hydrophilicity Mapping on Curved Surfaces

Hsien-Shun Liao, Sheng-Kai Tsao, Feng-Sheng Kao, Yi‐Chen Chen et al.
1 citations
IEEE Transactions on Instrumentation and Measurement
Surface Roughness and Optical Measurements
1.33
article

Laser Scanning System for Hydrophilicity Mapping on Curved Surfaces

Hsien-Shun Liao, Sheng-Kai Tsao, Feng-Sheng Kao, Yi‐Chen Chen, Y. Chao, Chai Yeh, Jen-You Chu
article en
1 citations

Abstract

Contact angle measurement is the most common technique for examining surface hydrophilicity. This technique usually involves a camera to capture the side view of a droplet. However, it often overlooks the distribution of hydrophilicity over the entire sample surface. In this study, a novel laser scanning technique was developed to obtain hydrophilicity maps of a curved sample surface with a maximum area of 175 mm × 250 mm. Moreover, a rotational tracking mechanism enabled the system to measure the curved surface with a tilt angle range of ±15°. The experiments yielded hydrophilicity maps of a polyimide film and glass slides. The results indicated that the developed laser scanning system was able to accurately determine the quantitative contact angle, height, and tilt angle images on the curved sample surface.

IEEE Transactions on Instrumentation and MeasurementVol. 74
National Taiwan University (TW), Industrial Technology Research Institute (TW)
Openalex Percentile: Top 25%
Surface Roughness and Optical Measurements
1.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.