Development and Performance Evaluation of a Benchtop Small-Animal PET/MRI Scanner

This study aims to develop a compact, low-cost, and high-performance benchtop small-animal PET/MRI scanner that achieves functional and anatomical image fusion. The system is designed to address challenges in cost reduction, spatial resolution, sensitivity, image quality, and quantitative accuracy. The PET/MRI system was developed with a parallel configuration, integrating a custom-designed PET scanner and a 0.5-T permanent magnet MRI system. Quantitative assessments included spatial resolution, sensitivity, image quality, and quantitative accuracy, as well as signal-to-noise ratio (SNR), geometric distortion (GD), and image uniformity for MRI. The spatial resolution at the axial center is 1.31 mm (axial), 1.26 mm (radial), and 1.22 mm (tangential), with a center sensitivity of 8.05% under a wide energy window. Image quality tests using an IQ phantom demonstrated a uniformity of 10.08 standard deviation, recovery coefficients (RC) ranging from 0.23 to 0.96, and spill-over ratios (SOR) of 0.08 and 0.18 in air and water regions, respectively. The MRI system achieved an SNR of 14.16 in phantom tests, a geometric distortion of less than 1%, and image uniformity of 90.13%. Fusion imaging of PET and MRI demonstrated high registration accuracy in both phantom and mouse studies, with complementary functional and anatomical information. The proposed PET/MRI system achieves high spatial resolution, sensitivity, image quality, and quantitative accuracy while maintaining a simple, low-cost design. The parallel configuration facilitates precise PET/MRI image fusion and allows for efficient multi-animal imaging. The results highlight the potential of this system for preclinical research and its feasibility for future in-vehicle imaging applications. Further optimization of the MRI system and data transmission methods will enhance its performance in high-activity studies and broaden its application scope, with potential applications in preclinical research and invehicle imaging.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Radiation and Plasma Medical Sciences
Published
2025-04-04
DOI
https://doi.org/10.1109/trpms.2025.3557789
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Performance Evaluation of a Benchtop Small-Animal PET/MRI Scanner

C Liu, Siwei Xie, Qiyu Peng, Ying Lin et al.
IEEE Transactions on Radiation and Plasma Medical Sciences
Medical Imaging Techniques and Applications
article

Development and Performance Evaluation of a Benchtop Small-Animal PET/MRI Scanner

C Liu, Siwei Xie, Qiyu Peng, Ying Lin, Xin Yu, Jing Zeng, Da Liang, Han Liu, Wenjing Zhu, Zhijun Zhao, Weimin Wang, Jianfeng Xu
article en

Abstract

This study aims to develop a compact, low-cost, and high-performance benchtop small-animal PET/MRI scanner that achieves functional and anatomical image fusion. The system is designed to address challenges in cost reduction, spatial resolution, sensitivity, image quality, and quantitative accuracy. The PET/MRI system was developed with a parallel configuration, integrating a custom-designed PET scanner and a 0.5-T permanent magnet MRI system. Quantitative assessments included spatial resolution, sensitivity, image quality, and quantitative accuracy, as well as signal-to-noise ratio (SNR), geometric distortion (GD), and image uniformity for MRI. The spatial resolution at the axial center is 1.31 mm (axial), 1.26 mm (radial), and 1.22 mm (tangential), with a center sensitivity of 8.05% under a wide energy window. Image quality tests using an IQ phantom demonstrated a uniformity of 10.08 standard deviation, recovery coefficients (RC) ranging from 0.23 to 0.96, and spill-over ratios (SOR) of 0.08 and 0.18 in air and water regions, respectively. The MRI system achieved an SNR of 14.16 in phantom tests, a geometric distortion of less than 1%, and image uniformity of 90.13%. Fusion imaging of PET and MRI demonstrated high registration accuracy in both phantom and mouse studies, with complementary functional and anatomical information. The proposed PET/MRI system achieves high spatial resolution, sensitivity, image quality, and quantitative accuracy while maintaining a simple, low-cost design. The parallel configuration facilitates precise PET/MRI image fusion and allows for efficient multi-animal imaging. The results highlight the potential of this system for preclinical research and its feasibility for future in-vehicle imaging applications. Further optimization of the MRI system and data transmission methods will enhance its performance in high-activity studies and broaden its application scope, with potential applications in preclinical research and invehicle imaging.

IEEE Transactions on Radiation and Plasma Medical SciencesVol. 9(8)
Shenzhen Bay Laboratory (CN), Peking University Shenzhen Hospital (CN), Huazhong University of Science and Technology (CN), Southern Medical University (CN)
National Natural Science Foundation of China, National Key Research and Development Program of China
Zero hunger
Openalex Percentile: Top 90%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.