Performance Prediction of a Highly Sensitive Optimized PCF-SPR Biosensor for Cancer Cell Detection Using MLP-Based ANN Model

Recent developments in surface plasmon resonance (SPR) sensors based on photonic crystal fiber (PCF) technology have greatly enhanced sensitivity. Nevertheless, existing configurations often face challenges related to design complexity and real-time application optimization. In this study, we present a straightforward and highly sensitive circular PCF-SPR biosensor tailored for the detection of early-stage cancer cells, with efficient performance across both visible and near-infrared spectrums. Using the Taguchi L<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">27</sub>(3<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">5</sup>) orthogonal array approach, we optimized five critical structural parameters: air hole diameters, pitch, and the thickness of the gold (Au) and titanium dioxide (TiO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub>) layers. The resulting sensor achieved remarkable spectral sensitivity of 18,000 nm/RIU and an amplitude sensitivity of 681.655 RIU<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup>. Designed to function across a wide refractive index range (1.29-1.40), the biosensor is particularly effective for identifying cervical, blood, and skin cancer cells, reaching peak sensitivity of 7,500 nm/RIU for cervical cancer detection. Additionally, performance prediction utilized machine learning techniques, specifically Multiple Linear Regression (MLR) and Multi-Layer Perceptron Artificial Neural Network (MLP-ANN) models. The MLP-ANN model demonstrated superior predictive accuracy, highlighting the potential of artificial intelligence in optimizing biosensor configurations for advanced cancer diagnostics.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-04-04
DOI
https://doi.org/10.1109/jsen.2025.3556292
Citations
13
Primary Topic
Acoustic Wave Resonator Technologies
Type
article
Field-Weighted Citation Impact
8.76
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Prediction of a Highly Sensitive Optimized PCF-SPR Biosensor for Cancer Cell Detection Using MLP-Based ANN Model

Sameh Kaziz, Chérif Dridi, Lamia Guedri-Knani
13 citations
IEEE Sensors Journal
Acoustic Wave Resonator Technologies
8.76
article

Performance Prediction of a Highly Sensitive Optimized PCF-SPR Biosensor for Cancer Cell Detection Using MLP-Based ANN Model

Sameh Kaziz, Chérif Dridi, Lamia Guedri-Knani
article en
13 citations

Abstract

Recent developments in surface plasmon resonance (SPR) sensors based on photonic crystal fiber (PCF) technology have greatly enhanced sensitivity. Nevertheless, existing configurations often face challenges related to design complexity and real-time application optimization. In this study, we present a straightforward and highly sensitive circular PCF-SPR biosensor tailored for the detection of early-stage cancer cells, with efficient performance across both visible and near-infrared spectrums. Using the Taguchi L<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">27</sub>(3<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">5</sup>) orthogonal array approach, we optimized five critical structural parameters: air hole diameters, pitch, and the thickness of the gold (Au) and titanium dioxide (TiO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub>) layers. The resulting sensor achieved remarkable spectral sensitivity of 18,000 nm/RIU and an amplitude sensitivity of 681.655 RIU<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup>. Designed to function across a wide refractive index range (1.29-1.40), the biosensor is particularly effective for identifying cervical, blood, and skin cancer cells, reaching peak sensitivity of 7,500 nm/RIU for cervical cancer detection. Additionally, performance prediction utilized machine learning techniques, specifically Multiple Linear Regression (MLR) and Multi-Layer Perceptron Artificial Neural Network (MLP-ANN) models. The MLP-ANN model demonstrated superior predictive accuracy, highlighting the potential of artificial intelligence in optimizing biosensor configurations for advanced cancer diagnostics.

IEEE Sensors JournalVol. 25(10)
Centre de Recherche en Microelectronique et Nanotechnologie, University of Sousse (TN)
Good health and well-being
Openalex Percentile: Top 2%
Acoustic Wave Resonator Technologies
8.76
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.