Hemodynamic Performance of a Self-Expanding Transcatheter Aortic Valve with an Intra-Annular Leaflet Position in Patients with a Small Aortic Annulus

<i>Background and Objectives</i>: Transcatheter aortic valve implantation is associated with a higher risk for elevated trans-prosthetic gradients and prosthesis-patient mismatch in patients with a small aortic annulus. We aimed to assess the short-term hemodynamic performance of self-expanding transcatheter aortic valves with an intra-annular leaflet position in patients with small aortic anatomies. <i>Materials and Methods</i>: Consecutive patients with small aortic annuli (annular area < 430 mm<sup>2</sup>), who underwent transcatheter aortic valve implantation with a self-expanding Portico or Navitor (Abbott Medical, St. Paul, MN, USA) transcatheter aortic valve between October 2017 and August 2024 at the University Medical Centre Ljubljana, Slovenia, were analyzed. The main endpoints were the post-procedural mean trans-prosthetic gradient, the presence of moderate or severe prosthesis-patient mismatch or paravalvular regurgitation. <i>Results</i>: Overall, 37 patients were included in the study (29 patients with a native aortic valve and 8 patients undergoing valve-in-valve transcatheter aortic valve implantation). The mean age was 81.6 ± 4.3 years, 32 patients (86.5%) were female. The median annular perimeter was 70.8 mm (interquartile range 67.3-74.1 mm) and the median annular area was 379 mm<sup>2</sup> (interquartile range 355-412 mm<sup>2</sup>). The post-procedural mean trans-prosthetic gradient was 9.0 ± 3.5 mmHg, with no cases with a mean gradient > 20 mmHg. Moderate and severe prosthesis-patient mismatch was observed in 21.2% and 3.0% of patients, respectively. Mild paravalvular regurgitation was noted in 44.1% of patients, there were no cases of moderate or severe paravalvular regurgitation. One patient (3.0%) had moderate valvular regurgitation. <i>Conclusions</i>: Self-expanding transcatheter aortic valves with an intra-annular leaflet position are associated with favorable hemodynamic performance in patients with a small aortic annulus.

Authors

Institutions

Publication Details

Journal
Medicina
Published
2025-04-03
DOI
https://doi.org/10.3390/medicina61040661
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hemodynamic Performance of a Self-Expanding Transcatheter Aortic Valve with an Intra-Annular Leaflet Position in Patients with a Small Aortic Annulus

Gregor Verček, Matjaž Bunc, Ole De Backer
Medicina
Cardiac Valve Diseases and Treatments
article

Hemodynamic Performance of a Self-Expanding Transcatheter Aortic Valve with an Intra-Annular Leaflet Position in Patients with a Small Aortic Annulus

Gregor Verček, Matjaž Bunc, Ole De Backer
article en

Abstract

<i>Background and Objectives</i>: Transcatheter aortic valve implantation is associated with a higher risk for elevated trans-prosthetic gradients and prosthesis-patient mismatch in patients with a small aortic annulus. We aimed to assess the short-term hemodynamic performance of self-expanding transcatheter aortic valves with an intra-annular leaflet position in patients with small aortic anatomies. <i>Materials and Methods</i>: Consecutive patients with small aortic annuli (annular area < 430 mm<sup>2</sup>), who underwent transcatheter aortic valve implantation with a self-expanding Portico or Navitor (Abbott Medical, St. Paul, MN, USA) transcatheter aortic valve between October 2017 and August 2024 at the University Medical Centre Ljubljana, Slovenia, were analyzed. The main endpoints were the post-procedural mean trans-prosthetic gradient, the presence of moderate or severe prosthesis-patient mismatch or paravalvular regurgitation. <i>Results</i>: Overall, 37 patients were included in the study (29 patients with a native aortic valve and 8 patients undergoing valve-in-valve transcatheter aortic valve implantation). The mean age was 81.6 ± 4.3 years, 32 patients (86.5%) were female. The median annular perimeter was 70.8 mm (interquartile range 67.3-74.1 mm) and the median annular area was 379 mm<sup>2</sup> (interquartile range 355-412 mm<sup>2</sup>). The post-procedural mean trans-prosthetic gradient was 9.0 ± 3.5 mmHg, with no cases with a mean gradient > 20 mmHg. Moderate and severe prosthesis-patient mismatch was observed in 21.2% and 3.0% of patients, respectively. Mild paravalvular regurgitation was noted in 44.1% of patients, there were no cases of moderate or severe paravalvular regurgitation. One patient (3.0%) had moderate valvular regurgitation. <i>Conclusions</i>: Self-expanding transcatheter aortic valves with an intra-annular leaflet position are associated with favorable hemodynamic performance in patients with a small aortic annulus.

MedicinaVol. 61(4)
University of Ljubljana (SI), Ljubljana University Medical Centre (SI), Copenhagen University Hospital (DK), Rigshospitalet (DK)
Good health and well-being
Openalex Percentile: Top 88%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.