Reducing femoral peri-implant fracture risk through optimized plate length and screw configuration – a biomechanical study

The findings of this study performed on synthetic bones indicate that from a biomechanical perspective long plates that extend into the femoral neck sustained higher failure loads compared to short plates. In addition, long plates fixed with a cortical neck screw further enhanced the construct strength and reduced the risk of peri-implant fractures compared to the use of a locking neck screw. Therefore, this study supports the use of long locking plates combined with use of cortical neck screws, particularly in high-risk patients, such as those with severe osteoporosis.

Authors

Institutions

Publication Details

Journal
Journal of Orthopaedic Surgery and Research
Published
2025-04-04
DOI
https://doi.org/10.1186/s13018-025-05753-9
Citations
4
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
8.03

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reducing femoral peri-implant fracture risk through optimized plate length and screw configuration – a biomechanical study

Ivan Zderic, Lionel Llano, Karl Kilian Stoffel, Luise Puls et al.
4 citations
Journal of Orthopaedic Surgery and Research
Orthopaedic implants and arthroplasty
8.03
article

Reducing femoral peri-implant fracture risk through optimized plate length and screw configuration – a biomechanical study

Ivan Zderic, Lionel Llano, Karl Kilian Stoffel, Luise Puls, Boyko Gueorguiev
article en
4 citations

Abstract

The findings of this study performed on synthetic bones indicate that from a biomechanical perspective long plates that extend into the femoral neck sustained higher failure loads compared to short plates. In addition, long plates fixed with a cortical neck screw further enhanced the construct strength and reduced the risk of peri-implant fractures compared to the use of a locking neck screw. Therefore, this study supports the use of long locking plates combined with use of cortical neck screws, particularly in high-risk patients, such as those with severe osteoporosis.

Journal of Orthopaedic Surgery and ResearchVol. 20(1)
AO Foundation (CH), Hospital Italiano de Buenos Aires (AR), University Hospital of Basel (CH)
Universität Basel, AO Foundation
Openalex Percentile: Top 3%
Orthopaedic implants and arthroplasty
8.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Reducing femoral peri-implant fracture risk through optimized plate length and screw configuration – a biomechanical study — Ivan Zderic, Lionel Llano, et al. · Journal of Orthopaedic Surgery and Research (2025) | TGRS Research Map | TGRS