A 0.05 mm3 diode-based single charged-particle real-time radiation detector for electron radiotherapy

Real-time radiation monitoring at the single-particle level is an unmet need for electron radiotherapy, especially for dose deposition to targets in motion or critical OARs. We have developed a first-in-class CMOS-based 0.05 mm<sup>3</sup> single electron sensitive detector. The chiplet integrates all the requisite electronics. The functionality of the system is verified under 6 and 9 MeV clinical electron beams. Percentage depth vs. pulse-width curves for 6 and 9 MeV beams are measured and verified using Monte-Carlo simulations. The proposed system has the potential to enhance the electron radiotherapy quality and safety, providing real-time dosimetry from multiple sites simultaneously.

Authors

Institutions

Publication Details

Journal
Physics and Imaging in Radiation Oncology
Published
2025-04-01
DOI
https://doi.org/10.1016/j.phro.2025.100762
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A 0.05 mm3 diode-based single charged-particle real-time radiation detector for electron radiotherapy

Michel M. Maharbiz, Rahul Lall, Kyoungtae Lee, Mekhail Anwar
Physics and Imaging in Radiation Oncology
Radiation Therapy and Dosimetry
article

A 0.05 mm3 diode-based single charged-particle real-time radiation detector for electron radiotherapy

Michel M. Maharbiz, Rahul Lall, Kyoungtae Lee, Mekhail Anwar
article en

Abstract

Real-time radiation monitoring at the single-particle level is an unmet need for electron radiotherapy, especially for dose deposition to targets in motion or critical OARs. We have developed a first-in-class CMOS-based 0.05 mm<sup>3</sup> single electron sensitive detector. The chiplet integrates all the requisite electronics. The functionality of the system is verified under 6 and 9 MeV clinical electron beams. Percentage depth vs. pulse-width curves for 6 and 9 MeV beams are measured and verified using Monte-Carlo simulations. The proposed system has the potential to enhance the electron radiotherapy quality and safety, providing real-time dosimetry from multiple sites simultaneously.

Physics and Imaging in Radiation OncologyVol. 34
University of California, San Francisco (US), Daegu Gyeongbuk Institute of Science and Technology (KR), University of California, Berkeley (US)
Affordable and clean energy
Openalex Percentile: Top 90%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A 0.05 mm3 diode-based single charged-particle real-time radiation detector for electron radiotherapy — Michel M. Maharbiz, Rahul Lall, et al. · Physics and Imaging in Radiation Oncology (2025) | TGRS Research Map | TGRS