In Vivo Brain B<sub>1</sub><sup>+</sup> Inhomogeneity Correction and NOE Image Enhancement at 7 T via Flexible Metasurfaces

Nuclear Overhauser effect (NOE) MRI has been used for in vivo brain imaging to assess lipid and protein composition and benefits from 7 T field strengths due to the larger chemical shift dispersion. However, a continuing challenge is signal drop off observed in regions such as the medial temporal lobes due to "standing wave" effects from shorter radiofrequency (RF) wavelengths at ultra-high fields. 2D periodic unit cell metasurfaces have been a promising approach for providing improvements in anatomical imaging but have not yet been evaluated in chemical exchange saturation transfer (CEST)-based sequences. Here, we report the use of metasurfaces for enhancement of NOE imaging as well as for improvement of Lorentzian line fitting of full Z-spectrum data. 3D NOE image data, B<sub>1</sub> <sup>+</sup> maps, and B<sub>0</sub> maps were acquired on five healthy volunteers using a 7 T MRI system with and without metasurfaces positioned near the temporal lobes. A frequency offset range of -5 to +5 ppm with additional separate acquisitions of ±20 and ±100 ppm offset images. A five-pool Lorentzian line fitting model was employed to fit and quantitatively compared magnetization transfer (MT), amide proton transfer (APT), amine, and relayed NOE (rNOE) metabolite pools. NOE<sub>MTR</sub>-weighted contrast maps were also calculated via Z-spectrum asymmetry analysis. The metasurfaces globally enhanced the transmit efficiency within the imaging slab by approximately 9.6% and reduced B<sub>1</sub> <sup>+</sup> inhomogeneity by approximately 16.6% and increased transmit efficiency by 55.8% in the temporal lobes. Amplitude fit maps showed decreases in contrast magnitude ranging from 1 to 16% and changes in image uniformity ranging from a 4.3 decrease to a 34.7% increase, while NOE<sub>MTR</sub>-weighted contrast maps demonstrated similar changes. The results presented here demonstrate that metasurfaces can enhance CEST-based techniques complementing previously reported benefits in anatomical imaging.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2025-04-02
DOI
https://doi.org/10.1002/nbm.70027
Citations
2
Primary Topic
Lanthanide and Transition Metal Complexes
Type
article
Field-Weighted Citation Impact
1.04

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In Vivo Brain B1+ Inhomogeneity Correction and NOE Image Enhancement at 7 T via Flexible Metasurfaces

Ravi Prakash Reddy Nanga, Ravinder Reddy, Anil Mathur, Wyger M. Brink et al.
2 citations
NMR in Biomedicine
Lanthanide and Transition Metal Complexes
1.04
article

In Vivo Brain B1+ Inhomogeneity Correction and NOE Image Enhancement at 7 T via Flexible Metasurfaces

Ravi Prakash Reddy Nanga, Ravinder Reddy, Anil Mathur, Wyger M. Brink, John A. Detre, Anshuman Swain, Paul S. Jacobs, Mark A. Elliott, Neil Wilson
article en
2 citations

Abstract

Nuclear Overhauser effect (NOE) MRI has been used for in vivo brain imaging to assess lipid and protein composition and benefits from 7 T field strengths due to the larger chemical shift dispersion. However, a continuing challenge is signal drop off observed in regions such as the medial temporal lobes due to "standing wave" effects from shorter radiofrequency (RF) wavelengths at ultra-high fields. 2D periodic unit cell metasurfaces have been a promising approach for providing improvements in anatomical imaging but have not yet been evaluated in chemical exchange saturation transfer (CEST)-based sequences. Here, we report the use of metasurfaces for enhancement of NOE imaging as well as for improvement of Lorentzian line fitting of full Z-spectrum data. 3D NOE image data, B<sub>1</sub> <sup>+</sup> maps, and B<sub>0</sub> maps were acquired on five healthy volunteers using a 7 T MRI system with and without metasurfaces positioned near the temporal lobes. A frequency offset range of -5 to +5 ppm with additional separate acquisitions of ±20 and ±100 ppm offset images. A five-pool Lorentzian line fitting model was employed to fit and quantitatively compared magnetization transfer (MT), amide proton transfer (APT), amine, and relayed NOE (rNOE) metabolite pools. NOE<sub>MTR</sub>-weighted contrast maps were also calculated via Z-spectrum asymmetry analysis. The metasurfaces globally enhanced the transmit efficiency within the imaging slab by approximately 9.6% and reduced B<sub>1</sub> <sup>+</sup> inhomogeneity by approximately 16.6% and increased transmit efficiency by 55.8% in the temporal lobes. Amplitude fit maps showed decreases in contrast magnitude ranging from 1 to 16% and changes in image uniformity ranging from a 4.3 decrease to a 34.7% increase, while NOE<sub>MTR</sub>-weighted contrast maps demonstrated similar changes. The results presented here demonstrate that metasurfaces can enhance CEST-based techniques complementing previously reported benefits in anatomical imaging.

NMR in BiomedicineVol. 38(5)
University of Pennsylvania (US), University of Twente (NL)
National Institutes of Health, National Institute on Aging, National Institute of Biomedical Imaging and Bioengineering
Openalex Percentile: Top 26%
Lanthanide and Transition Metal Complexes
1.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.