Micellar media effect on the ultrasensitive quantitation of a diuretic medication at nano-scale levels with environmentally benign impact

A novel micelle-augmented spectrofluorimetric method is proposed for the ultrasensitive estimation of bumetanide (BUM) at nanoscale concentrations. The method utilizes the unique properties of micelles to enhance the fluorescence intensity of BUM and measures its native fluorescence at 415 nm after excitation at 267 nm. The proposed method was optimized by evaluating the effect of organized media, buffer pH, and diluting solvent. The method validity was further assessed following the ICH guidelines, where excellent linearity was obtained over a concentration range of 40.0-400.0 ng mL<sup>-1</sup>, with a correlation coefficient of 0.9999 and a low limit of detection (LOD) of 5.31 ng mL<sup>-1</sup>. The method was further applied for the determination of BUM in different dosage forms with % recoveries greater than 98%, as well as for content uniformity testing. Ultimately, a comprehensive assessment of the method's environmental impact was performed using different metrics, highlighting the eco-friendly nature of the method and underlining its potential for sustainable analytical practices in pharmaceutical research and beyond.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2025-01-01
DOI
https://doi.org/10.1039/d5ay00015g
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Micellar media effect on the ultrasensitive quantitation of a diuretic medication at nano-scale levels with environmentally benign impact

Samah Abo El Abass, Manal A. Alossaimi, Asmaa Kamal El‐Deen, Abdulmalik Saleh Alfawaz Altamimi
Analytical Methods
Analytical chemistry methods development
article

Micellar media effect on the ultrasensitive quantitation of a diuretic medication at nano-scale levels with environmentally benign impact

Samah Abo El Abass, Manal A. Alossaimi, Asmaa Kamal El‐Deen, Abdulmalik Saleh Alfawaz Altamimi
article en

Abstract

A novel micelle-augmented spectrofluorimetric method is proposed for the ultrasensitive estimation of bumetanide (BUM) at nanoscale concentrations. The method utilizes the unique properties of micelles to enhance the fluorescence intensity of BUM and measures its native fluorescence at 415 nm after excitation at 267 nm. The proposed method was optimized by evaluating the effect of organized media, buffer pH, and diluting solvent. The method validity was further assessed following the ICH guidelines, where excellent linearity was obtained over a concentration range of 40.0-400.0 ng mL<sup>-1</sup>, with a correlation coefficient of 0.9999 and a low limit of detection (LOD) of 5.31 ng mL<sup>-1</sup>. The method was further applied for the determination of BUM in different dosage forms with % recoveries greater than 98%, as well as for content uniformity testing. Ultimately, a comprehensive assessment of the method's environmental impact was performed using different metrics, highlighting the eco-friendly nature of the method and underlining its potential for sustainable analytical practices in pharmaceutical research and beyond.

Analytical MethodsVol. 17(16)
Prince Sattam Bin Abdulaziz University (SA), Mansoura University (EG)
Prince Sattam bin Abdulaziz University
Responsible consumption and production
Openalex Percentile: Top 93%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.