Assessment of handheld Raman spectroscopy for forensic analysis of dark‐colored bulk explosive fuel–oxidizer mixtures

The field identification of explosives is critical for crime response, requiring specialized protocols and often the support of Explosive Ordnance Disposal (EOD) teams to ensure safety. Handheld Raman spectrometers are widely used for this purpose due to their portability, nondestructive analysis, and ability to detect both organic and inorganic compounds with minimal sample preparation. However, their effectiveness is limited for dark-colored explosives-such as black powder, flash powder, and sulfur-chlorate explosives-commonly encountered in criminal activities. These mixtures pose unique challenges, including poor spectral quality caused by light absorption and the risk of ignition during direct analysis. This study addresses these challenges by introducing a simple and effective methodology for the safe identification of oxidizing salts in dark-colored fuel-oxidizer mixtures using handheld Raman spectrometers. The approach involves aqueous extraction followed by Raman analysis of the extract, improving safety and yielding reliable results by circumventing the limitations of direct solid analysis. Results confirmed that direct analysis of these mixtures is unsafe and ineffective, with three mixtures igniting during testing and others providing insufficient spectral data. In contrast, the aqueous extraction method enabled the successful identification of oxidizing salts in all tested samples using basic materials commonly found in crime scene kits. This technique supports field investigations, such as the seizure of suspected explosive materials, helping in decision-making during on-site investigations.

Authors

Institutions

Publication Details

Journal
Journal of Forensic Sciences
Published
2025-04-03
DOI
https://doi.org/10.1111/1556-4029.70038
Citations
4
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
6.54
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of handheld Raman spectroscopy for forensic analysis of dark‐colored bulk explosive fuel–oxidizer mixtures

Lúcio Paulo Lima Logrado, B. Neto, Bruna Silva
4 citations
Journal of Forensic Sciences
Spectroscopy Techniques in Biomedical and Chemical Research
6.54
article

Assessment of handheld Raman spectroscopy for forensic analysis of dark‐colored bulk explosive fuel–oxidizer mixtures

Lúcio Paulo Lima Logrado, B. Neto, Bruna Silva
article en
4 citations

Abstract

The field identification of explosives is critical for crime response, requiring specialized protocols and often the support of Explosive Ordnance Disposal (EOD) teams to ensure safety. Handheld Raman spectrometers are widely used for this purpose due to their portability, nondestructive analysis, and ability to detect both organic and inorganic compounds with minimal sample preparation. However, their effectiveness is limited for dark-colored explosives-such as black powder, flash powder, and sulfur-chlorate explosives-commonly encountered in criminal activities. These mixtures pose unique challenges, including poor spectral quality caused by light absorption and the risk of ignition during direct analysis. This study addresses these challenges by introducing a simple and effective methodology for the safe identification of oxidizing salts in dark-colored fuel-oxidizer mixtures using handheld Raman spectrometers. The approach involves aqueous extraction followed by Raman analysis of the extract, improving safety and yielding reliable results by circumventing the limitations of direct solid analysis. Results confirmed that direct analysis of these mixtures is unsafe and ineffective, with three mixtures igniting during testing and others providing insufficient spectral data. In contrast, the aqueous extraction method enabled the successful identification of oxidizing salts in all tested samples using basic materials commonly found in crime scene kits. This technique supports field investigations, such as the seizure of suspected explosive materials, helping in decision-making during on-site investigations.

Journal of Forensic SciencesVol. 70(4)
Universidade de Brasília (BR), Federal Police of Brazil (BR)
Peace, Justice and strong institutions
Openalex Percentile: Top 4%
Spectroscopy Techniques in Biomedical and Chemical Research
6.54
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessment of handheld Raman spectroscopy for forensic analysis of dark‐colored bulk explosive fuel–oxidizer mixtures — Lúcio Paulo Lima Logrado, B. Neto, et al. · Journal of Forensic Sciences (2025) | TGRS Research Map | TGRS