A new method for the rapid determination of sodium percarbonate in aqueous samples using a modified HPLC setup

Sodium percarbonate (SPC) is a widely used oxidant with applications in environmental remediation, especially within advanced oxidation processes (AOPs). Despite its prevalence, traditional methods for SPC quantification are often limited by complexity, cost, or lack of adaptability, creating a need for rapid, reliable, and scalable analytical approaches. This study presents a novel method for SPC quantification using a modified high-performance liquid chromatography with visible detection (HPLC-VIS) system. The key innovation lies in replacing the conventional separation column with a narrow-diameter loop reactor made of simple PEEK tubing, allowing SPC to react with acidified potassium iodide directly within the system. This modification eliminates the need for separate sample pretreatment, simplifies the analytical workflow, and enables real-time reaction monitoring while using standard HPLC equipment available in most laboratories. The method demonstrated high repeatability, reproducibility, and strong linearity (<i>R</i> <sup>2</sup> > 0.99) across a range of pH values and in complex matrices, including highly saline and organic pollutant-containing samples. The method effectively monitored residual SPC levels in AOP-treated tramadol samples, where it confirmed continued SPC activity post-degradation of the target compound, indicating potential for comprehensive degradation of byproducts. Additionally, tests on a commercial SPC-based detergent (Vanish) validated the method's applicability for real-world samples. Overall, this HPLC-based technique provides a streamlined, environmentally friendly, and robust solution for SPC quantification, offering significant advantages for both research and industrial applications involving SPC in various water matrices.

Authors

Institutions

Publication Details

Journal
RSC Advances
Published
2025-01-01
DOI
https://doi.org/10.1039/d4ra08825e
Citations
2
Primary Topic
Pharmaceutical and Antibiotic Environmental Impacts
Type
article
Field-Weighted Citation Impact
1.01

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A new method for the rapid determination of sodium percarbonate in aqueous samples using a modified HPLC setup

Abbas Baalbaki, Antoine Ghauch, Weam Bou Karroum, Amir Nasreddine et al.
2 citations
RSC Advances
Pharmaceutical and Antibiotic Environmental Impacts
1.01
article

A new method for the rapid determination of sodium percarbonate in aqueous samples using a modified HPLC setup

Abbas Baalbaki, Antoine Ghauch, Weam Bou Karroum, Amir Nasreddine, Sarah Ghazali
article en
2 citations

Abstract

Sodium percarbonate (SPC) is a widely used oxidant with applications in environmental remediation, especially within advanced oxidation processes (AOPs). Despite its prevalence, traditional methods for SPC quantification are often limited by complexity, cost, or lack of adaptability, creating a need for rapid, reliable, and scalable analytical approaches. This study presents a novel method for SPC quantification using a modified high-performance liquid chromatography with visible detection (HPLC-VIS) system. The key innovation lies in replacing the conventional separation column with a narrow-diameter loop reactor made of simple PEEK tubing, allowing SPC to react with acidified potassium iodide directly within the system. This modification eliminates the need for separate sample pretreatment, simplifies the analytical workflow, and enables real-time reaction monitoring while using standard HPLC equipment available in most laboratories. The method demonstrated high repeatability, reproducibility, and strong linearity (<i>R</i> <sup>2</sup> > 0.99) across a range of pH values and in complex matrices, including highly saline and organic pollutant-containing samples. The method effectively monitored residual SPC levels in AOP-treated tramadol samples, where it confirmed continued SPC activity post-degradation of the target compound, indicating potential for comprehensive degradation of byproducts. Additionally, tests on a commercial SPC-based detergent (Vanish) validated the method's applicability for real-world samples. Overall, this HPLC-based technique provides a streamlined, environmentally friendly, and robust solution for SPC quantification, offering significant advantages for both research and industrial applications involving SPC in various water matrices.

RSC AdvancesVol. 15(13)
American University of Beirut (LB)
United States Agency for International Development, American University of Beirut, U.S.-Middle East Partnership Initiative, National Academy of Sciences, University Research Board, American University of Beirut
Openalex Percentile: Top 28%
Pharmaceutical and Antibiotic Environmental Impacts
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.