A passive flow microreactor for urine creatinine test

Chronic kidney disease (CKD) significantly affects people's health and quality of life and presents a high economic burden worldwide. There are well-established biomarkers for CKD diagnosis. However, the existing routine standard tests are lab-based and governed by strict regulations. Creatinine is commonly measured as a filtration biomarker in blood to determine estimated Glomerular Filtration Rate (eGFR), as well as a normalization factor to calculate urinary Albumin-to-Creatinine Ratio (uACR) for CKD evaluation. In this study, we developed a passive flow microreactor for colorimetric urine creatinine measurement (uCR-Chip), which is highly amenable to integration with our previously developed microfluidic urine albumin assay. The combination of the 2-phase pressure compensation (2-PPC) technique and microfluidic channel network design accurately controls the fluidic mixing ratio and chemical reaction. Together with an optimized observation window (OW) design, a uniform and stable detection signal was achieved within 7 min. The color signal was measured by a simple USB microscope-based platform to quantify creatinine concentration in the sample. The combination of the custom in-house photomask production techniques and dry-film photoresist-based lithography enabled rapid iterative design optimization and precise chip fabrication. The developed assay achieved a dynamic linear detection range up to 40 mM and a lower limit of detection (LOD) of 0.521 mM, meeting the clinical precision requirements (comparable to existing point-of-care (PoC) systems). The microreactor was validated using creatinine standards spiked into commercial artificial urine that mimics physiological matrix. Our results showed acceptable recovery rate and low matrix effect, especially for the low creatinine concentration range in comparison to a commercial PoC uACR test. Altogether, the developed uCR-Chip offers a viable PoC test for CKD assessment and provides a potential platform technology to measure various disease biomarkers.

Authors

Institutions

Publication Details

Journal
Microsystems & Nanoengineering
Published
2025-04-02
DOI
https://doi.org/10.1038/s41378-025-00880-z
Citations
2
Primary Topic
3D Printing in Biomedical Research
Type
article
Field-Weighted Citation Impact
1.35

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A passive flow microreactor for urine creatinine test

AbdulRazaq Sokoro, René P. Zahedi, Dumitru Tomsa, Francis Lin et al.
2 citations
Microsystems & Nanoengineering
3D Printing in Biomedical Research
1.35
article

A passive flow microreactor for urine creatinine test

AbdulRazaq Sokoro, René P. Zahedi, Dumitru Tomsa, Francis Lin, Amanda Stefanson, Paul Komenda, Yang Liu, Navdeep Tangri, Claudio Rigatto, Xiaoou Ren
article en
2 citations

Abstract

Chronic kidney disease (CKD) significantly affects people's health and quality of life and presents a high economic burden worldwide. There are well-established biomarkers for CKD diagnosis. However, the existing routine standard tests are lab-based and governed by strict regulations. Creatinine is commonly measured as a filtration biomarker in blood to determine estimated Glomerular Filtration Rate (eGFR), as well as a normalization factor to calculate urinary Albumin-to-Creatinine Ratio (uACR) for CKD evaluation. In this study, we developed a passive flow microreactor for colorimetric urine creatinine measurement (uCR-Chip), which is highly amenable to integration with our previously developed microfluidic urine albumin assay. The combination of the 2-phase pressure compensation (2-PPC) technique and microfluidic channel network design accurately controls the fluidic mixing ratio and chemical reaction. Together with an optimized observation window (OW) design, a uniform and stable detection signal was achieved within 7 min. The color signal was measured by a simple USB microscope-based platform to quantify creatinine concentration in the sample. The combination of the custom in-house photomask production techniques and dry-film photoresist-based lithography enabled rapid iterative design optimization and precise chip fabrication. The developed assay achieved a dynamic linear detection range up to 40 mM and a lower limit of detection (LOD) of 0.521 mM, meeting the clinical precision requirements (comparable to existing point-of-care (PoC) systems). The microreactor was validated using creatinine standards spiked into commercial artificial urine that mimics physiological matrix. Our results showed acceptable recovery rate and low matrix effect, especially for the low creatinine concentration range in comparison to a commercial PoC uACR test. Altogether, the developed uCR-Chip offers a viable PoC test for CKD assessment and provides a potential platform technology to measure various disease biomarkers.

Microsystems & NanoengineeringVol. 11(1)
University of Science and Technology of China (CN), Research Manitoba (CA), Hefei Institutes of Physical Science (CN), University of Manitoba (CA)
University of Manitoba
Openalex Percentile: Top 21%
3D Printing in Biomedical Research
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.