Development of low cost ZnO based chemi resistive biosensor for the detection of vitamin B6 mediated by quantum dots

In this study, we developed a chemi-resistive sensor for vitamin B6 mediated by CdTe quantum dots (Cadmium Telluride QDs) utilizing ZnO-based thin films through the spin-coating sol-gel technique annealed at 500 °C. The sensor successfully recognized vitamin B6 (Pyridoxine) in concentrations ranging from 2 to 10 µM by employing CdTe quantum dots (Cadmium Telluride QDs) on the ZnO thin film. This detection was achieved by implementing an amperometric (I-V) method, typically operating at a working voltage below 2 V. From the slope of the calibration curve, the sensitivity, and the limit of detection values are estimated to be 7.56 ± 0.92 nA/µM and 0.906 µM (n = 5), respectively. This study conducted electrochemical impedance spectroscopy (EIS) in conjunction with current-voltage (I-V) measurements. The results obtained from EIS are consistent with the current response observed in the I-V measurements. The sensing mechanism primarily relies on the charge transfer phenomenon (electrostatic attraction) between the analyte (vitamin B6 mediated by CdTe quantum dots) and the ZnO thin film. In summary, our work introduces a simple, rapid, and cost-effective ZnO thin film-based sensing device for detecting vitamin B6, mediated by CdTe QDs. This sensor holds promise for a wide range of applications, from pharmaceutical quality control to point-of-care diagnostics and routine vitamin B screening.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-04-02
DOI
https://doi.org/10.1038/s41598-025-95892-0
Citations
3
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
2.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of low cost ZnO based chemi resistive biosensor for the detection of vitamin B6 mediated by quantum dots

Bhavana Anchan, Suresh D. Kulkarni, Shounak De, Saritha Kamath U. et al.
3 citations
Scientific Reports
Advanced biosensing and bioanalysis techniques
2.42
article

Development of low cost ZnO based chemi resistive biosensor for the detection of vitamin B6 mediated by quantum dots

Bhavana Anchan, Suresh D. Kulkarni, Shounak De, Saritha Kamath U., Kavita Pandey, Ajeetkumar Patil
article en
3 citations

Abstract

In this study, we developed a chemi-resistive sensor for vitamin B6 mediated by CdTe quantum dots (Cadmium Telluride QDs) utilizing ZnO-based thin films through the spin-coating sol-gel technique annealed at 500 °C. The sensor successfully recognized vitamin B6 (Pyridoxine) in concentrations ranging from 2 to 10 µM by employing CdTe quantum dots (Cadmium Telluride QDs) on the ZnO thin film. This detection was achieved by implementing an amperometric (I-V) method, typically operating at a working voltage below 2 V. From the slope of the calibration curve, the sensitivity, and the limit of detection values are estimated to be 7.56 ± 0.92 nA/µM and 0.906 µM (n = 5), respectively. This study conducted electrochemical impedance spectroscopy (EIS) in conjunction with current-voltage (I-V) measurements. The results obtained from EIS are consistent with the current response observed in the I-V measurements. The sensing mechanism primarily relies on the charge transfer phenomenon (electrostatic attraction) between the analyte (vitamin B6 mediated by CdTe quantum dots) and the ZnO thin film. In summary, our work introduces a simple, rapid, and cost-effective ZnO thin film-based sensing device for detecting vitamin B6, mediated by CdTe QDs. This sensor holds promise for a wide range of applications, from pharmaceutical quality control to point-of-care diagnostics and routine vitamin B screening.

Scientific ReportsVol. 15(1)
Manipal Academy of Higher Education (IN), Centre for Nano and Soft Matter Sciences (IN)
Indian Institute of Science, Department of Science and Technology, Ministry of Science and Technology, India, Ministry of Education, India, Ministry of Electronics and Information technology
Openalex Percentile: Top 12%
Advanced biosensing and bioanalysis techniques
2.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.