Integrating Vacancies and Defect Levels in Heterojunctions to Synergistically Enhance the Performance of H<sub>2</sub>S Chemiresistors for Periodontitis Diagnosis

Exhaled breath is considered an important source of samples and a reservoir of biomarkers, especially for disease diagnosis. In this study, we developed an ultrasensitive point-of-care gas sensor for the analysis of hydrogen sulfide (H<sub>2</sub>S), which is a typical biomarker for periodontitis. A high-performance metal oxide semiconductor (MOS)-based chemiresistive H<sub>2</sub>S sensor was developed by integrating Fe-doped MoO<sub>3-x</sub> onto TiO<sub>2</sub> nanotube arrays. The substitution of Fe atoms into MoO<sub>3-x</sub> not only induced oxygen vacancies, but also generated defect levels in the MoO<sub>3-x</sub>/TiO<sub>2</sub> heterostructure, thus synergistically activating the gas sensing reaction at room temperature under ambient light. The resulting gas sensor exhibited ultrahigh sensitivity, fast response/recovery ability, and wide-range response to H<sub>2</sub>S concentrations up to 400 ppm. Furthermore, the sensing device maintained more than 95% of its original response at 70% relative humidity. With a subparts-per-billion limit of detection (the LOD for H<sub>2</sub>S was 0.34 ppb), the present sensor represents the most sensitive H<sub>2</sub>S chemiresistor reported to date for room-temperature, real-time monitoring of H<sub>2</sub>S concentration changes in the breath of healthy subjects, as well as for distinguishing breath samples of periodontitis patients and healthy individuals. This study utilizes the synergistic action of defects to provide an effective route for developing MOS-based ultrasensitive H<sub>2</sub>S sensors for periodontitis diagnosis.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2025-04-03
DOI
https://doi.org/10.1021/acssensors.5c00205
Citations
12
Primary Topic
Gas Sensing Nanomaterials and Sensors
Type
article
Field-Weighted Citation Impact
8.77

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integrating Vacancies and Defect Levels in Heterojunctions to Synergistically Enhance the Performance of H2S Chemiresistors for Periodontitis Diagnosis

Zhida Gao, Yan‐Yan Song, Pei Song, Quanxin Li et al.
12 citations
ACS Sensors
Gas Sensing Nanomaterials and Sensors
8.77
article

Integrating Vacancies and Defect Levels in Heterojunctions to Synergistically Enhance the Performance of H2S Chemiresistors for Periodontitis Diagnosis

Zhida Gao, Yan‐Yan Song, Pei Song, Quanxin Li, Hongbo Zhang, Ruxiang Xu, Jingwen Xu, Yang Du, Chenxi Zhao, Jilong Zheng
article en
12 citations

Abstract

Exhaled breath is considered an important source of samples and a reservoir of biomarkers, especially for disease diagnosis. In this study, we developed an ultrasensitive point-of-care gas sensor for the analysis of hydrogen sulfide (H<sub>2</sub>S), which is a typical biomarker for periodontitis. A high-performance metal oxide semiconductor (MOS)-based chemiresistive H<sub>2</sub>S sensor was developed by integrating Fe-doped MoO<sub>3-x</sub> onto TiO<sub>2</sub> nanotube arrays. The substitution of Fe atoms into MoO<sub>3-x</sub> not only induced oxygen vacancies, but also generated defect levels in the MoO<sub>3-x</sub>/TiO<sub>2</sub> heterostructure, thus synergistically activating the gas sensing reaction at room temperature under ambient light. The resulting gas sensor exhibited ultrahigh sensitivity, fast response/recovery ability, and wide-range response to H<sub>2</sub>S concentrations up to 400 ppm. Furthermore, the sensing device maintained more than 95% of its original response at 70% relative humidity. With a subparts-per-billion limit of detection (the LOD for H<sub>2</sub>S was 0.34 ppb), the present sensor represents the most sensitive H<sub>2</sub>S chemiresistor reported to date for room-temperature, real-time monitoring of H<sub>2</sub>S concentration changes in the breath of healthy subjects, as well as for distinguishing breath samples of periodontitis patients and healthy individuals. This study utilizes the synergistic action of defects to provide an effective route for developing MOS-based ultrasensitive H<sub>2</sub>S sensors for periodontitis diagnosis.

ACS SensorsVol. 10(4)
College of Medical Sciences (NP), Criminal Investigation Police University of China (CN), Jinhua Central Hospital (CN), Zhejiang University (CN), Universidad del Noreste (MX), China Medical University (CN)
National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities
Openalex Percentile: Top 2%
Gas Sensing Nanomaterials and Sensors
8.77
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.