Comparative Analysis of Intraocular Lens Power Calculation Formulas (Kane, Barrett Universal II, Hill–Radial Basis Function, and Ladas Super Formula): Which One Is More Accurate?

<b>Background:</b> The most widely used contemporary intraocular lens power calculation formulas are the Kane formula, Barrett Universal II formula, Hill-Radial Basis Function, and Ladas Super Formula, each of which was developed to improve postoperative refractive accuracy. This study aims to conduct a comprehensive comparative analysis of these formulas to evaluate their predictive accuracy across diverse biometric profiles. <b>Methods:</b> A total of 210 eyes that met the inclusion criteria were analyzed in this study. This study was designed as a retrospective observational investigation. The biometric parameters of the intraocular lens were evaluated using the ARGOS optical biometer. Refractive intraocular lens power calculations were performed using the formulas, and the resulting values were systematically compared to assess predictive accuracy. In our research, a parametric approach was adopted by applying ANOVA repeated measures analysis. Multiple measurements were evaluated through homogeneity of covariances. Pairwise comparisons between formula-derived values were conducted using the Bonferroni test to identify significant differences. A paired-sample <i>t</i>-test was used to compare the spherical equivalent levels calculated at the first and last controls. Potential correlations were examined using Pearson correlation analysis. <b>Results:</b> A statistically significant difference was observed between formulas. The differences among the formulas were caused by the values obtained from the Ladas Super Formula being significantly higher than the others. There was a statistically significant positive correlation between the data obtained from the formulas. The spheric equivalent values were similar, with no statistically significant difference. <b>Conclusions:</b> This study reinforces the notion that modern intraocular lens power calculation formulas exhibit a high degree of accuracy and correlation in predicting postoperative refractive outcomes.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-04-03
DOI
https://doi.org/10.3390/jcm14072443
Citations
3
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
4.06
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Analysis of Intraocular Lens Power Calculation Formulas (Kane, Barrett Universal II, Hill–Radial Basis Function, and Ladas Super Formula): Which One Is More Accurate?

Mihnea Munteanu, Horia Tudor Stanca, Leila Al Barri, Diana‐Maria Dărăbuş et al.
3 citations
Journal of Clinical Medicine
Ophthalmology and Visual Impairment Studies
4.06
article

Comparative Analysis of Intraocular Lens Power Calculation Formulas (Kane, Barrett Universal II, Hill–Radial Basis Function, and Ladas Super Formula): Which One Is More Accurate?

Mihnea Munteanu, Horia Tudor Stanca, Leila Al Barri, Diana‐Maria Dărăbuş, Andreea-Talida Tîrziu, Ionela-Iasmina Yasar, Servet Yasar
article en
3 citations

Abstract

<b>Background:</b> The most widely used contemporary intraocular lens power calculation formulas are the Kane formula, Barrett Universal II formula, Hill-Radial Basis Function, and Ladas Super Formula, each of which was developed to improve postoperative refractive accuracy. This study aims to conduct a comprehensive comparative analysis of these formulas to evaluate their predictive accuracy across diverse biometric profiles. <b>Methods:</b> A total of 210 eyes that met the inclusion criteria were analyzed in this study. This study was designed as a retrospective observational investigation. The biometric parameters of the intraocular lens were evaluated using the ARGOS optical biometer. Refractive intraocular lens power calculations were performed using the formulas, and the resulting values were systematically compared to assess predictive accuracy. In our research, a parametric approach was adopted by applying ANOVA repeated measures analysis. Multiple measurements were evaluated through homogeneity of covariances. Pairwise comparisons between formula-derived values were conducted using the Bonferroni test to identify significant differences. A paired-sample <i>t</i>-test was used to compare the spherical equivalent levels calculated at the first and last controls. Potential correlations were examined using Pearson correlation analysis. <b>Results:</b> A statistically significant difference was observed between formulas. The differences among the formulas were caused by the values obtained from the Ladas Super Formula being significantly higher than the others. There was a statistically significant positive correlation between the data obtained from the formulas. The spheric equivalent values were similar, with no statistically significant difference. <b>Conclusions:</b> This study reinforces the notion that modern intraocular lens power calculation formulas exhibit a high degree of accuracy and correlation in predicting postoperative refractive outcomes.

Journal of Clinical MedicineVol. 14(7)
Carol Davila University of Medicine and Pharmacy (RO), Victor Babeș University of Medicine and Pharmacy Timișoara (RO)
Openalex Percentile: Top 7%
Ophthalmology and Visual Impairment Studies
4.06
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.