Fast-Track Hemostasis by an Automated Fastener for Decannulation of an Antegrade Cardioplegia Cannula in Robotic Cardiac Surgery
In robotic cardiac surgery, many knot ties must be made with a knot pusher by the patient's side surgeon. However, knot-pusher ties are characterized by weak attachment pressure. Therefore, we decided to use the Cor-knot automated fastener (LSI Solutions) to achieve hemostasis at the antegrade cardioplegia cannulation site. This technique allowed us to obtain speedy and reliable hemostasis at the antegrade cardioplegia cannulation site in robotic cardiac surgery.
Authors
- Masato Mutsuga (ORCID: https://orcid.org/0000-0001-9740-2142)
- Tomonari Uemura (ORCID: https://orcid.org/0009-0007-9729-3020)
- Toshikuni Yamamoto
- Yasunari Hayashi
Institutions
- Nagoya University (JP)
Publication Details
- Journal
- Annals of Thoracic Surgery Short Reports
- Published
- 2025-04-03
- DOI
- https://doi.org/10.1016/j.atssr.2025.03.014
- Citations
- 1
- Primary Topic
- Cardiac and Coronary Surgery Techniques
- Type
- article
- Field-Weighted Citation Impact
- 2.01