Impeller Position in a Magnetically Levitated Rotodynamic Blood Pump and Its Impact on In-Silico Hemocompatibility

In magnetically levitated rotodynamic blood pumps (RPBs), the impeller position depends on a balance of electromagnetic and fluid dynamic forces. The aim of this study was to describe the impeller position of the HeartMate 3 over a wide range of operating conditions and assess its potential impact on hemocompatibility. Three-dimensional impeller positions were measured using a transparent HeartMate 3 pump casing, laser distance measurements, and a high-speed camera. Accompanying computational fluid dynamic (CFD) hemocompatibility predictions of a displaced and centered impeller at a typical operating point were compared. Impeller positions vary substantially with different operating points with a maximum axial displacement of 223 µm at 7 L/min and 7,000 rpm and a maximum radial displacement of 145 µm at 0 L/min and 7,000 rpm. In CFD, a displaced impeller had only a minor influence on global pump parameters (<2%) at an operating point of 5 L/min and 6,000 rpm. However, deviations in local flow metrics of up to 9% were observed compared with a centered impeller simulation. We here provide the impeller position of the HeartMate 3 over the full operating range (0-9 L/min, 3,000-7,000 rpm) to support further research, including more extensive CFD simulations.

Authors

Institutions

Publication Details

Journal
ASAIO Journal
Published
2025-04-03
DOI
https://doi.org/10.1097/mat.0000000000002434
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impeller Position in a Magnetically Levitated Rotodynamic Blood Pump and Its Impact on In-Silico Hemocompatibility

Daniel Zimpfer, Bente Thamsen, Philipp Aigner, Marcus Granegger et al.
ASAIO Journal
Mechanical Circulatory Support Devices
article

Impeller Position in a Magnetically Levitated Rotodynamic Blood Pump and Its Impact on In-Silico Hemocompatibility

Daniel Zimpfer, Bente Thamsen, Philipp Aigner, Marcus Granegger, Michael Röhrich, Marko Grujic, Stefan Jakubek, Rosmarie Schoefbeck
article en

Abstract

In magnetically levitated rotodynamic blood pumps (RPBs), the impeller position depends on a balance of electromagnetic and fluid dynamic forces. The aim of this study was to describe the impeller position of the HeartMate 3 over a wide range of operating conditions and assess its potential impact on hemocompatibility. Three-dimensional impeller positions were measured using a transparent HeartMate 3 pump casing, laser distance measurements, and a high-speed camera. Accompanying computational fluid dynamic (CFD) hemocompatibility predictions of a displaced and centered impeller at a typical operating point were compared. Impeller positions vary substantially with different operating points with a maximum axial displacement of 223 µm at 7 L/min and 7,000 rpm and a maximum radial displacement of 145 µm at 0 L/min and 7,000 rpm. In CFD, a displaced impeller had only a minor influence on global pump parameters (<2%) at an operating point of 5 L/min and 6,000 rpm. However, deviations in local flow metrics of up to 9% were observed compared with a centered impeller simulation. We here provide the impeller position of the HeartMate 3 over the full operating range (0-9 L/min, 3,000-7,000 rpm) to support further research, including more extensive CFD simulations.

ASAIO JournalVol. 71(11)
TU Wien (AT), Medical University of Vienna (AT)
Affordable and clean energy
Openalex Percentile: Top 94%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.