Occupational radiation exposure during blood sample collection post I-131 therapeutic administration in thyroid cancer patients

The blood sampling required for the verification of dose delivered during radioactive iodine (<sup>131</sup>I) therapy is a source of radiation exposure for healthcare staff. This study aims to estimate staff exposures, using Monte Carlo modelling, as well as experimental measurements. The study further aimed to validate the models with staff exposure measurements and examine the impact of protective measures on the procedure. The clinical set-up of blood sampling post<sup>131</sup>I patient administration, within a dedicated<sup>131</sup>I ablation therapy suite, was modelled using EGSnrc Monte Carlo simulations (MCSs). The dose scoring regions representing deep dose (Hp(10)) and skin dose (Hp(0.07)) were estimated and validated with an experimental approach and clinical monitoring of staff members using electronic personal dosimeters. MCSs and experimental values did not show significant differences between the two approaches (<i>p</i>> 0.05), with simulated values having lower uncertainties. It is demonstrated that the model is capable of being tailored to clinical scenarios at any centre. The simulations were corroborated with dosimetry data of blood sampling from 14 patients post administering 3.7 GBq<sup>131</sup>I, amounting to a total of 54 measurements from 14 staff members. With the employed protective shielding, none of the staff were exposed to a dose rate approaching the annual dose constraint of 0.3 mSv.yr<sup>-1</sup>. The experimental and MCS data show good agreement with the clinical data, demonstrating the advantages of MCS approaches for providing useful information for planning and carrying out risk assessments before implementing a new dosimetry practice.

Authors

Institutions

Publication Details

Journal
Journal of Radiological Protection
Published
2025-04-03
DOI
https://doi.org/10.1088/1361-6498/adc8b3
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Occupational radiation exposure during blood sample collection post I-131 therapeutic administration in thyroid cancer patients

Jennie Cooke, Amna Juma Al-Jabri, Seán Cournane, Marie‐Louise Healy
Journal of Radiological Protection
Radiation Dose and Imaging
article

Occupational radiation exposure during blood sample collection post I-131 therapeutic administration in thyroid cancer patients

Jennie Cooke, Amna Juma Al-Jabri, Seán Cournane, Marie‐Louise Healy
article en

Abstract

The blood sampling required for the verification of dose delivered during radioactive iodine (<sup>131</sup>I) therapy is a source of radiation exposure for healthcare staff. This study aims to estimate staff exposures, using Monte Carlo modelling, as well as experimental measurements. The study further aimed to validate the models with staff exposure measurements and examine the impact of protective measures on the procedure. The clinical set-up of blood sampling post<sup>131</sup>I patient administration, within a dedicated<sup>131</sup>I ablation therapy suite, was modelled using EGSnrc Monte Carlo simulations (MCSs). The dose scoring regions representing deep dose (Hp(10)) and skin dose (Hp(0.07)) were estimated and validated with an experimental approach and clinical monitoring of staff members using electronic personal dosimeters. MCSs and experimental values did not show significant differences between the two approaches (<i>p</i>> 0.05), with simulated values having lower uncertainties. It is demonstrated that the model is capable of being tailored to clinical scenarios at any centre. The simulations were corroborated with dosimetry data of blood sampling from 14 patients post administering 3.7 GBq<sup>131</sup>I, amounting to a total of 54 measurements from 14 staff members. With the employed protective shielding, none of the staff were exposed to a dose rate approaching the annual dose constraint of 0.3 mSv.yr<sup>-1</sup>. The experimental and MCS data show good agreement with the clinical data, demonstrating the advantages of MCS approaches for providing useful information for planning and carrying out risk assessments before implementing a new dosimetry practice.

Journal of Radiological ProtectionVol. 45(2)
Trinity College Dublin (IE), Children's Health Ireland at Crumlin (IE), St. Vincent's University Hospital (IE), Sultan Qaboos University Hospital (OM), St. James's Hospital (IE), Sultan Qaboos University (OM)
Good health and well-being
Openalex Percentile: Top 90%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.