Short Lifetime Radical Metal Cluster Scintillator

Abstract Metal clusters, an emerging class of scintillator materials, have attracted much attention owing to their inherently high X‐ray absorption, mild synthesis conditions, low toxicity, strong luminescence, and large Stokes shift. However, the decay lifetime of metal clusters is usually on the order of microseconds, which is unfavorable for safety inspection, nondestructive testing, and medical imaging. Here, the open‐shell luminescent radical ligand was used to construct the first radical cluster scintillator Cu 2 I 2 (L) 4 . The spin‐allowed doublet emission of Cu 2 I 2 (L) 4 theoretically enabled 100% exciton utilization and exhibited a short radiation decay lifetime on the nanosecond scale. Cu 2 I 2 (L) 4 can be fabricated into a flexible scintillator screen for X‐ray imaging, achieving a high resolution of 30.7 LP mm −1 . More importantly, the Cu 2 I 2 (L) 4 scintillator screen has no residual images during X‐ray imaging. This work reports the first luminescent metal cluster with a radical ligand and presents a new strategy for constructing short lifetime X‐ray scintillators.

Authors

Institutions

Publication Details

Journal
Angewandte Chemie
Published
2025-04-03
DOI
https://doi.org/10.1002/ange.202503457
Citations
3
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
5.65
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Short Lifetime Radical Metal Cluster Scintillator

Shuang‐Quan Zang, Jia‐Wang Yuan, Zhao‐Yang Wang, Ying Lei et al.
3 citations
Angewandte Chemie
Radiation Detection and Scintillator Technologies
5.65
article

Short Lifetime Radical Metal Cluster Scintillator

Shuang‐Quan Zang, Jia‐Wang Yuan, Zhao‐Yang Wang, Ying Lei, Kai Li, Qi Yang, Ruoyu Cao, Zi‐Ying Gao, Qiuchen Peng
article en
3 citations

Abstract

Abstract Metal clusters, an emerging class of scintillator materials, have attracted much attention owing to their inherently high X‐ray absorption, mild synthesis conditions, low toxicity, strong luminescence, and large Stokes shift. However, the decay lifetime of metal clusters is usually on the order of microseconds, which is unfavorable for safety inspection, nondestructive testing, and medical imaging. Here, the open‐shell luminescent radical ligand was used to construct the first radical cluster scintillator Cu 2 I 2 (L) 4 . The spin‐allowed doublet emission of Cu 2 I 2 (L) 4 theoretically enabled 100% exciton utilization and exhibited a short radiation decay lifetime on the nanosecond scale. Cu 2 I 2 (L) 4 can be fabricated into a flexible scintillator screen for X‐ray imaging, achieving a high resolution of 30.7 LP mm −1 . More importantly, the Cu 2 I 2 (L) 4 scintillator screen has no residual images during X‐ray imaging. This work reports the first luminescent metal cluster with a radical ligand and presents a new strategy for constructing short lifetime X‐ray scintillators.

Angewandte ChemieVol. 137(24)
Zhengzhou University (CN), Institute of Molecular Functional Materials (CN)
Openalex Percentile: Top 4%
Radiation Detection and Scintillator Technologies
5.65
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.