Enhanced deep tissue imaging using long wavelength conjugate spectral domain OCT with balanced detection

Deep tissue imaging is achieved with a long-wavelength conjugate SD-OCT (Spectral-Domain Optical Coherence Tomography) combined with balanced detection. The use of long wavelength and conjugate configuration serves to reduce scattering and counteract spectrometer roll off, respectively, in SD-OCT, thereby enhancing imaging depth. A 1550nm OCT system is designed with the use of supercontinuum source (SuperK FIANIUM FIU-6 OCT) and Cobra 1600 spectrometer with bandwidth 1450-1690 nm. Balanced detection is employed to mitigate the excess noise associated with the supercontinuum source and to minimize the autocorrelation noise artefacts. This advanced technique leveraging long wavelength and BD in conjugate SD-OCT has allowed us to achieve optical imaging depths exceeding 4 mm in chicken breast tissue and scotch tape.

Authors

Institutions

Publication Details

Published
2025-04-03
DOI
https://doi.org/10.1117/12.3046387
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced deep tissue imaging using long wavelength conjugate spectral domain OCT with balanced detection

Gauri Arora, Steven G. Adie, Santosh Balakrishnan
2 links
Optical Coherence Tomography Applications
article

Enhanced deep tissue imaging using long wavelength conjugate spectral domain OCT with balanced detection

Gauri Arora, Steven G. Adie, Santosh Balakrishnan
article en

Abstract

Deep tissue imaging is achieved with a long-wavelength conjugate SD-OCT (Spectral-Domain Optical Coherence Tomography) combined with balanced detection. The use of long wavelength and conjugate configuration serves to reduce scattering and counteract spectrometer roll off, respectively, in SD-OCT, thereby enhancing imaging depth. A 1550nm OCT system is designed with the use of supercontinuum source (SuperK FIANIUM FIU-6 OCT) and Cobra 1600 spectrometer with bandwidth 1450-1690 nm. Balanced detection is employed to mitigate the excess noise associated with the supercontinuum source and to minimize the autocorrelation noise artefacts. This advanced technique leveraging long wavelength and BD in conjugate SD-OCT has allowed us to achieve optical imaging depths exceeding 4 mm in chicken breast tissue and scotch tape.

Cornell University (US)
Openalex Percentile: Top 94%
Optical Coherence Tomography Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.