A Novel Magnetic Suppression Technique for Asymmetric-Distributed Magnetic Disturbance in CMS for MCG Test

The cylindrical magnetic shield (CMS) with the advantages of easy-process, low-cost and portable-mobility is widely utilized in magnetocardiography (MCG) for recording the weak biomagnetic field of cardiac. The one-side-open structure of CMS leads to excessive flux leakage and uneven-distributed magnetic field, which cause extra degradation of sensitivity and signal noise ratio of MCG test. Therefore, an enhanced magnetic suppression technique for reducing the asymmetric-distributed remanence and magnetic noise inside CMS is proposed in this paper. This method introduces the Fourier series with half-angle component for asymmetric compensation field generation and combines the analytic method to model and weaken coupling effect impact. The feedback control is employed in the compensation system for static and dynamic magnetic interference containment. The asymmetric-distributed remanence <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">B<sub>y</sub></i> and <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">B<sub>z</sub></i> is suppressed near zero, and the magnetic noise of <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">B<sub>y</sub></i> and <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">B<sub>z</sub></i> at 0.01 Hz is restrained from 59.3 to 0.06 pT/Hz<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1/2</sup> and 92.7 to 0.24 pT/Hz<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1/2</sup> with the inhibition rate of 29.95 dB and 25.87 dB respectively. The MCG test with high signal-to-noise ratio is then realized inside the MCS with the asymmetric compensation system.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3555703
Citations
12
Primary Topic
Magnetic Properties and Applications
Type
article
Field-Weighted Citation Impact
5.13

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Magnetic Suppression Technique for Asymmetric-Distributed Magnetic Disturbance in CMS for MCG Test

Xu Zhang, Shuai Yuan, Jianzhi Yang, Minxia Shi et al.
12 citations
IEEE Transactions on Instrumentation and Measurement
Magnetic Properties and Applications
5.13
article

A Novel Magnetic Suppression Technique for Asymmetric-Distributed Magnetic Disturbance in CMS for MCG Test

Xu Zhang, Shuai Yuan, Jianzhi Yang, Minxia Shi, Ao Zhang, Yuzheng Ma, Leran Zhang
article en
12 citations

Abstract

The cylindrical magnetic shield (CMS) with the advantages of easy-process, low-cost and portable-mobility is widely utilized in magnetocardiography (MCG) for recording the weak biomagnetic field of cardiac. The one-side-open structure of CMS leads to excessive flux leakage and uneven-distributed magnetic field, which cause extra degradation of sensitivity and signal noise ratio of MCG test. Therefore, an enhanced magnetic suppression technique for reducing the asymmetric-distributed remanence and magnetic noise inside CMS is proposed in this paper. This method introduces the Fourier series with half-angle component for asymmetric compensation field generation and combines the analytic method to model and weaken coupling effect impact. The feedback control is employed in the compensation system for static and dynamic magnetic interference containment. The asymmetric-distributed remanence <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">B<sub>y</sub></i> and <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">B<sub>z</sub></i> is suppressed near zero, and the magnetic noise of <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">B<sub>y</sub></i> and <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">B<sub>z</sub></i> at 0.01 Hz is restrained from 59.3 to 0.06 pT/Hz<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1/2</sup> and 92.7 to 0.24 pT/Hz<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1/2</sup> with the inhibition rate of 29.95 dB and 25.87 dB respectively. The MCG test with high signal-to-noise ratio is then realized inside the MCS with the asymmetric compensation system.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Beihang University (CN)
National Natural Science Foundation of China
Climate action
Openalex Percentile: Top 4%
Magnetic Properties and Applications
5.13
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.