<i>In vivo</i> human neurite exchange time imaging at 500 mT/m diffusion gradients
Evaluating tissue microstructure and membrane integrity in the living human brain through diffusion-water exchange imaging is challenging due to requirements for a high signal-to-noise ratio and short diffusion times dictated by relatively fast exchange processes. The goal of this work was to demonstrate the feasibility of <i>in vivo</i> imaging of tissue micro-geometries and water exchange within the brain gray matter using the state-of-the-art Connectome 2.0 scanner equipped with an ultra-high-performance gradient system (maximum gradient strength=500 mT/m, maximum slew rate=600 T/m/s). We performed diffusion MRI measurements in 15 healthy volunteers at multiple diffusion times (13-30 ms) and <i>b</i>-values up to 17.5 ms/μm<sup>2</sup>. The anisotropic Kärger model was applied to estimate the apparent exchange time between intra-neurite and extracellular water in gray matter. The estimated exchange time across the cortical ribbon was around (median±interquartile range) 13±8 ms on Connectome 2.0, substantially faster than that measured using an imaging protocol compatible with Connectome 1.0-alike systems on the same cohort. Our investigation suggested that the apparent exchange time estimation using a Connectome 1.0 compatible protocol was more prone to residual noise floor biases due to the small time-dependent signal contrasts across diffusion times when the exchange is fast (≤20 ms). Furthermore, spatial variation of exchange time was observed across the cortex, where the motor cortex, somatosensory cortex and visual cortex exhibit longer apparent exchange times compared to other cortical regions. Non-linear fitting for the anisotropic Kärger model was accelerated 100 times using a GPU-based pipeline compared to the conventional CPU-based approach. This study highlighted the importance of the chosen diffusion times and measures to address Rician noise in dMRI data, which can have a substantial impact on the estimated apparent exchange time and require extra attention when comparing the results between various hardware setups.
Authors
- Sune Nørhøj Jespersen (ORCID: https://orcid.org/0000-0003-3146-4329)
- Hong‐Hsi Lee (ORCID: https://orcid.org/0000-0002-3663-6559)
- José P. Marques (ORCID: https://orcid.org/0000-0001-8157-8864)
- Jonas Lynge Olesen (ORCID: https://orcid.org/0000-0003-4624-9816)
- Kwok‐Shing Chan (ORCID: https://orcid.org/0000-0001-8427-169X)
- Dmitry S. Novikov (ORCID: https://orcid.org/0000-0002-4213-3050)
- Santiago Coelho (ORCID: https://orcid.org/0000-0002-1039-4803)
- Susie Y. Huang (ORCID: https://orcid.org/0000-0003-2950-7254)
- Yixin Ma (ORCID: https://orcid.org/0000-0002-2080-9013)
- Hansol Lee (ORCID: https://orcid.org/0000-0003-2112-1197)
Institutions
- Harvard University (US)
- Radboud University Nijmegen (NL)
- Aarhus University (DK)
- Massachusetts General Hospital (US)
- Athinoula A. Martinos Center for Biomedical Imaging (US)
- Advanced Imaging Research (United States) (US)
- New York University (US)
Publication Details
- Journal
- Imaging Neuroscience
- Published
- 2025-01-01
- DOI
- https://doi.org/10.1162/imag_a_00544
- Citations
- 6
- Primary Topic
- Advanced Neuroimaging Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 8.16
Funders
- National Research Foundation
- Danmarks Grundforskningsfond
- Lundbeckfonden
- H. Lundbeck A/S
- National Institutes of Health
- National Institute of Neurological Disorders and Stroke
- National Institute of Biomedical Imaging and Bioengineering
- National Institute of Dental and Craniofacial Research
- National Center for Research Resources