MyoStep: Feature-Based GNN Model for Estimating Knee Joint Angles by Fusing Signals From sEMG and IMU

Smooth and continuous control over exoskeletons remains challenging for practical applications. Applying surface electromyography (sEMG) and inertial measurement unit (IMU) to predict knee joint angles faces several issues, including complex deployment, precise locating muscles and equipment interfering with movement. Furthermore, present estimation methods seldom consider the topology of the device. We propose a MyoStep method that applies a feature-based Graph Neural Network (GNN) model to estimate knee joint angles by combining signals from sEMG electrodes and IMU. First, the self-developed leg band collects signals and its sensors are mapped as the graph nodes. Features are extracted and then weighted by the Neighborhood Component Feature Selection algorithm, and the top five weighted features are exploited as graph properties. Furthermore, the topological links between the sEMG electrodes and IMU are associated with the edges of the graph, and the mean correlation coefficients between neighboring nodes are computed as the edge attributes. Finally, the graph features are obtained by ReadOut function of the model, and then fed into the full-connected layers to estimate knee joint angles. The sensor deployment of MyoStep is simpler and causes less interference. Additionally, the estimated knee joint angles’ root mean square error (RMSE), coefficient of determination (R2) and pearson correlation coefficient (CC) are 2.82°, 0.993 and 0.997, respectively. Compared to the models of CNN, BiLSTM, and GNNbaseline, the R2 and CC of MyoStep increase by 18% and 7%, and the RMSE decreases by 78%. Therefore, the MyoStep method has considerable applicability in simplified deployment and precise control of exoskeleton robots.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-04-03
DOI
https://doi.org/10.1109/jsen.2025.3555668
Citations
1
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MyoStep: Feature-Based GNN Model for Estimating Knee Joint Angles by Fusing Signals From sEMG and IMU

Lihui Feng, Jihua Lu, Wei Chen, Bian Wu et al.
1 citations
IEEE Sensors Journal
Muscle activation and electromyography studies
0.67
article

MyoStep: Feature-Based GNN Model for Estimating Knee Joint Angles by Fusing Signals From sEMG and IMU

Lihui Feng, Jihua Lu, Wei Chen, Bian Wu, Dewei Liu
article en
1 citations

Abstract

Smooth and continuous control over exoskeletons remains challenging for practical applications. Applying surface electromyography (sEMG) and inertial measurement unit (IMU) to predict knee joint angles faces several issues, including complex deployment, precise locating muscles and equipment interfering with movement. Furthermore, present estimation methods seldom consider the topology of the device. We propose a MyoStep method that applies a feature-based Graph Neural Network (GNN) model to estimate knee joint angles by combining signals from sEMG electrodes and IMU. First, the self-developed leg band collects signals and its sensors are mapped as the graph nodes. Features are extracted and then weighted by the Neighborhood Component Feature Selection algorithm, and the top five weighted features are exploited as graph properties. Furthermore, the topological links between the sEMG electrodes and IMU are associated with the edges of the graph, and the mean correlation coefficients between neighboring nodes are computed as the edge attributes. Finally, the graph features are obtained by ReadOut function of the model, and then fed into the full-connected layers to estimate knee joint angles. The sensor deployment of MyoStep is simpler and causes less interference. Additionally, the estimated knee joint angles’ root mean square error (RMSE), coefficient of determination (R2) and pearson correlation coefficient (CC) are 2.82°, 0.993 and 0.997, respectively. Compared to the models of CNN, BiLSTM, and GNNbaseline, the R2 and CC of MyoStep increase by 18% and 7%, and the RMSE decreases by 78%. Therefore, the MyoStep method has considerable applicability in simplified deployment and precise control of exoskeleton robots.

IEEE Sensors JournalVol. 25(10)
Beijing Institute of Technology (CN), Ministry of Industry and Information Technology (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 33%
Muscle activation and electromyography studies
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.