A Novel Four-Channel Sensor Array with Dual Enzymes and Dual Modes for Evaluating Total Antioxidant Capacity in Foods

Antioxidants are essential for preventing cellular and organ damage caused by reactive oxygen species (ROS). Consequently, the total antioxidant capacity (TAC) of food products was a critical criterion for assessing their quality. This study presented a novel dual-mode, four-channel sensor array platform for the highly sensitive detection of TAC, which employed the exceptional dual enzyme activity of mesoporous silica nanoparticles loaded with iron and nitrogen codoped carbon quantum dots (Fe,N-CQDs@MSNs) through pattern recognition methods. The dual-enzyme-like nanocatalysts exhibited: (1) Peroxidase-like activity in which Fe,N-CQDs@MSNs facilitated the activation of H<sub>2</sub>O<sub>2</sub>, yielding hydroxyl radicals (<sup>•</sup>OH); and (2) photoresponsive oxidative activity, where Fe,N-CQDs@MSNs generated <sup>•</sup>OH, superoxide anions (<sup>•</sup>O<sub>2</sub><sup>-</sup>), and singlet oxygen (<sup>1</sup>O<sub>2</sub>) under UV light at 365 nm. These ROS oxidized 3,3',5,5'-tetramethylbenzidine (TMB) from colorless to blue, accompanied by fluorescence quenching in Fe,N-CQDs@MSNs. Upon adding four antioxidants ascorbic acid (AA), glutathione (GSH), cysteine (Cys), and dopamine (DA), the reactive intermediates were eliminated to varying degrees, leading to distinct UV and fluorescence responses as specific "fingerprints" for the sensor array. Multivariate statistical approaches, including principal component analysis (PCA) and hierarchical clustering analysis (HCA), enabled the distinct classification of the four antioxidants, achieving a detection limit of 1 μM. Additionally, the sensor array enabled the identification of varying concentrations of individual antioxidants as well as mixtures in different proportions. Finally, the proposed method was effectively employed for the quantitative determination of TAC in diverse food samples, yielding satisfactory results and demonstrating its potential for TAC detection in food products.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2025-04-03
DOI
https://doi.org/10.1021/acssensors.4c03609
Citations
18
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
13.15
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Four-Channel Sensor Array with Dual Enzymes and Dual Modes for Evaluating Total Antioxidant Capacity in Foods

Zhanjun Yang, Xiashi Zhu, Xiaoqiao Yang, Xiang Li et al.
18 citations
ACS Sensors
Electrochemical sensors and biosensors
13.15
article

A Novel Four-Channel Sensor Array with Dual Enzymes and Dual Modes for Evaluating Total Antioxidant Capacity in Foods

Zhanjun Yang, Xiashi Zhu, Xiaoqiao Yang, Xiang Li, Jun Wu
article en
18 citations

Abstract

Antioxidants are essential for preventing cellular and organ damage caused by reactive oxygen species (ROS). Consequently, the total antioxidant capacity (TAC) of food products was a critical criterion for assessing their quality. This study presented a novel dual-mode, four-channel sensor array platform for the highly sensitive detection of TAC, which employed the exceptional dual enzyme activity of mesoporous silica nanoparticles loaded with iron and nitrogen codoped carbon quantum dots (Fe,N-CQDs@MSNs) through pattern recognition methods. The dual-enzyme-like nanocatalysts exhibited: (1) Peroxidase-like activity in which Fe,N-CQDs@MSNs facilitated the activation of H<sub>2</sub>O<sub>2</sub>, yielding hydroxyl radicals (<sup>•</sup>OH); and (2) photoresponsive oxidative activity, where Fe,N-CQDs@MSNs generated <sup>•</sup>OH, superoxide anions (<sup>•</sup>O<sub>2</sub><sup>-</sup>), and singlet oxygen (<sup>1</sup>O<sub>2</sub>) under UV light at 365 nm. These ROS oxidized 3,3',5,5'-tetramethylbenzidine (TMB) from colorless to blue, accompanied by fluorescence quenching in Fe,N-CQDs@MSNs. Upon adding four antioxidants ascorbic acid (AA), glutathione (GSH), cysteine (Cys), and dopamine (DA), the reactive intermediates were eliminated to varying degrees, leading to distinct UV and fluorescence responses as specific "fingerprints" for the sensor array. Multivariate statistical approaches, including principal component analysis (PCA) and hierarchical clustering analysis (HCA), enabled the distinct classification of the four antioxidants, achieving a detection limit of 1 μM. Additionally, the sensor array enabled the identification of varying concentrations of individual antioxidants as well as mixtures in different proportions. Finally, the proposed method was effectively employed for the quantitative determination of TAC in diverse food samples, yielding satisfactory results and demonstrating its potential for TAC detection in food products.

ACS SensorsVol. 10(4)
Yangzhou University (CN)
Zero hunger
Openalex Percentile: Top 1%
Electrochemical sensors and biosensors
13.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.