Development and Validation of a Novel HPLC-UV Method for the Quantification of Hyaluronic Acid in Anti-Aging Creams

This study introduces a novel, rapid, and cost-effective high-performance liquid chromatography (HPLC-UV) method for the direct quantification of HA in anti-aging creams without requiring derivatization. Chromatographic separation was performed on a reversed-phase C18 (5 μm × 4.6 mm × 150 mm) column, using an acetonitrile-acetate buffer (80:20, v/v) mobile phase at 0.9 mL/min flow rate. UV detection at 230 nm provided high selectivity. The method demonstrated excellent linearity (R² = 0.9997) across 0.1–30 μg/mL, with limits of detection (LOD) and quantification (LOQ) of 0.03 and 0.1 μg/mL, respectively. Validation was conducted per ICH guidelines, confirming high accuracy, precision (RSD < 1.88%), robustness, and repeatability, with minimal matrix interference. Compared to existing HA quantification methods, this optimized HPLC-UV technique offers superior sensitivity, speed, and simplicity, making it an ideal tool for routine analysis in cosmetic formulations.

Authors

Institutions

Publication Details

Journal
METHODS AND OBJECTS OF CHEMICAL ANALYSIS
Published
2025-01-01
DOI
https://doi.org/10.17721/moca.2025.72-76
Primary Topic
Proteoglycans and glycosaminoglycans research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Validation of a Novel HPLC-UV Method for the Quantification of Hyaluronic Acid in Anti-Aging Creams

Burhan Ceylan
METHODS AND OBJECTS OF CHEMICAL ANALYSIS
Proteoglycans and glycosaminoglycans research
article

Development and Validation of a Novel HPLC-UV Method for the Quantification of Hyaluronic Acid in Anti-Aging Creams

Burhan Ceylan
article en

Abstract

This study introduces a novel, rapid, and cost-effective high-performance liquid chromatography (HPLC-UV) method for the direct quantification of HA in anti-aging creams without requiring derivatization. Chromatographic separation was performed on a reversed-phase C18 (5 μm × 4.6 mm × 150 mm) column, using an acetonitrile-acetate buffer (80:20, v/v) mobile phase at 0.9 mL/min flow rate. UV detection at 230 nm provided high selectivity. The method demonstrated excellent linearity (R² = 0.9997) across 0.1–30 μg/mL, with limits of detection (LOD) and quantification (LOQ) of 0.03 and 0.1 μg/mL, respectively. Validation was conducted per ICH guidelines, confirming high accuracy, precision (RSD < 1.88%), robustness, and repeatability, with minimal matrix interference. Compared to existing HA quantification methods, this optimized HPLC-UV technique offers superior sensitivity, speed, and simplicity, making it an ideal tool for routine analysis in cosmetic formulations.

METHODS AND OBJECTS OF CHEMICAL ANALYSISVol. 20(1)
Harran University (TR)
Openalex Percentile: Top 93%
Proteoglycans and glycosaminoglycans research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.