Integration of Specific Aeration Demand (SAD) into Flux-Step Test for Submerged Membrane Bioreactor

This study proposes a novel methodology to assess fouling that complements the flux-step test (FST) by integrating aeration-step tests (ASTs) to optimise the specific aeration demand (SADm) for ultrafiltration hollow-fibre (UF-HF) submerged membranes in membrane bioreactor (MBR) configurations. Three membranes with distinct manufacturing processes-non-thermal-induced phase separation (NIPS) and thermal-induced phase separation (TIPS)-were evaluated under continuous and intermittent aeration. The AST revealed that the critical SADm has a range of 0.1-0.5 m<sup>3</sup>·m<sup>-2</sup>·h<sup>-1</sup> for continuous aeration and 0.1-0.2 m<sup>3</sup>·m<sup>-2</sup>·h<sup>-1</sup> for intermittent aeration. NIPS membranes with homogeneous structures were less prone to fouling under intermittent aeration, while TIPS membranes with a heterogeneous structure exhibited better recovery under continuous aeration, reflecting distinct fouling dynamics. Findings indicate that the FST alone does not fully represent operational conditions, as aeration efficiency is linked to membrane structure and aeration mode. By combining the FST with ASTs, our approach enables tailored fouling control strategies, reducing energy consumption and improving MBR performance. These insights are critical for advancing toward energy-efficient wastewater treatment technologies.

Authors

Institutions

Publication Details

Journal
Membranes
Published
2025-04-03
DOI
https://doi.org/10.3390/membranes15040111
Primary Topic
Membrane Separation Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integration of Specific Aeration Demand (SAD) into Flux-Step Test for Submerged Membrane Bioreactor

Ignasi Rodríguez‐Roda, Hèctor Monclús, Gaëtan Blandin, Albert Galizia et al.
Membranes
Membrane Separation Technologies
article

Integration of Specific Aeration Demand (SAD) into Flux-Step Test for Submerged Membrane Bioreactor

Ignasi Rodríguez‐Roda, Hèctor Monclús, Gaëtan Blandin, Albert Galizia, Joaquím Comas
article en

Abstract

This study proposes a novel methodology to assess fouling that complements the flux-step test (FST) by integrating aeration-step tests (ASTs) to optimise the specific aeration demand (SADm) for ultrafiltration hollow-fibre (UF-HF) submerged membranes in membrane bioreactor (MBR) configurations. Three membranes with distinct manufacturing processes-non-thermal-induced phase separation (NIPS) and thermal-induced phase separation (TIPS)-were evaluated under continuous and intermittent aeration. The AST revealed that the critical SADm has a range of 0.1-0.5 m<sup>3</sup>·m<sup>-2</sup>·h<sup>-1</sup> for continuous aeration and 0.1-0.2 m<sup>3</sup>·m<sup>-2</sup>·h<sup>-1</sup> for intermittent aeration. NIPS membranes with homogeneous structures were less prone to fouling under intermittent aeration, while TIPS membranes with a heterogeneous structure exhibited better recovery under continuous aeration, reflecting distinct fouling dynamics. Findings indicate that the FST alone does not fully represent operational conditions, as aeration efficiency is linked to membrane structure and aeration mode. By combining the FST with ASTs, our approach enables tailored fouling control strategies, reducing energy consumption and improving MBR performance. These insights are critical for advancing toward energy-efficient wastewater treatment technologies.

MembranesVol. 15(4)
Universitat de Girona (ES), Catalan Institute for Water Research (ES)
“la Caixa” Foundation, Agència de Gestió d'Ajuts Universitaris i de Recerca
Clean water and sanitation
Openalex Percentile: Top 92%
Membrane Separation Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Integration of Specific Aeration Demand (SAD) into Flux-Step Test for Submerged Membrane Bioreactor — Ignasi Rodríguez‐Roda, Hèctor Monclús, et al. · Membranes (2025) | TGRS Research Map | TGRS