Bioelectrical Impedance Analysis and How it Correlates to Intracardiac Hemodynamics in Patients with Congenital Heart Disease

Bioelectrical impedance analysis (BIA) is a noninvasive tool that can estimate volume status using fluid compartment ratios. Previous studies have demonstrated that BIA can be used to help manage heart failure using the edema index (EI), which is the ratio of extracellular water (ECW) to total body water (TBW). This study set out to better define the relationship between BIA fluid compartment estimations and invasive hemodynamic measurements, in the context of pediatric and congenital heart disease. 52 individuals underwent 59 elective catheterizations and BIA. Data from the BIAs were compared with the hemodynamic catheterization data. The median age at the time of catheterization was 16.6 [13.5, 19.6] years (63% < 18 years-old), and 29% were female. In multivariable analysis, EI (β = 103.5 ± 47.9, p = 0.04), body mass index (BMI) (β = 0.16 ± 0.07, p = 0.02), and current Fontan circulation (β = 3.06 ± 0.96, p = 0.002) were statistically significant predictors of pulmonary capillary wedge pressure (PCWP). Individuals with an EI ≥ 0.39 had a statistically significant higher PCWP compared to those with an EI < 0.39 (12 [11, 17] vs. 10 [8, 12], = 0.05), with an area under the curve (AUC) of 0.76 (95% CI 0.65, 0.87). There was no statistically significant mean difference between the pre-catheterization and either post-catheterization EI (- 0.0001 mean difference (0% change), p = 0.92), or body fat mass (BFM) (+ 0.035 mean difference (0.2% change), p = 0.81). This study suggests that BIA, and more specifically EI, can noninvasively provide valuable information about hemodynamic data. BIA provides a quick, easy, non-invasive method for assessing and managing the volume status in individuals with congenital heart disease.

Authors

Institutions

Publication Details

Journal
Pediatric Cardiology
Published
2025-04-02
DOI
https://doi.org/10.1007/s00246-025-03840-6
Primary Topic
Body Composition Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bioelectrical Impedance Analysis and How it Correlates to Intracardiac Hemodynamics in Patients with Congenital Heart Disease

Clifford Chin, Sarosh Percy Batlivala, Hunter Cope, David A. Katz et al.
Pediatric Cardiology
Body Composition Measurement Techniques
article

Bioelectrical Impedance Analysis and How it Correlates to Intracardiac Hemodynamics in Patients with Congenital Heart Disease

Clifford Chin, Sarosh Percy Batlivala, Hunter Cope, David A. Katz, Adam W. Powell, Zhiqian Gao, Alexander R. Opotowsky
article en

Abstract

Bioelectrical impedance analysis (BIA) is a noninvasive tool that can estimate volume status using fluid compartment ratios. Previous studies have demonstrated that BIA can be used to help manage heart failure using the edema index (EI), which is the ratio of extracellular water (ECW) to total body water (TBW). This study set out to better define the relationship between BIA fluid compartment estimations and invasive hemodynamic measurements, in the context of pediatric and congenital heart disease. 52 individuals underwent 59 elective catheterizations and BIA. Data from the BIAs were compared with the hemodynamic catheterization data. The median age at the time of catheterization was 16.6 [13.5, 19.6] years (63% < 18 years-old), and 29% were female. In multivariable analysis, EI (β = 103.5 ± 47.9, p = 0.04), body mass index (BMI) (β = 0.16 ± 0.07, p = 0.02), and current Fontan circulation (β = 3.06 ± 0.96, p = 0.002) were statistically significant predictors of pulmonary capillary wedge pressure (PCWP). Individuals with an EI ≥ 0.39 had a statistically significant higher PCWP compared to those with an EI < 0.39 (12 [11, 17] vs. 10 [8, 12], = 0.05), with an area under the curve (AUC) of 0.76 (95% CI 0.65, 0.87). There was no statistically significant mean difference between the pre-catheterization and either post-catheterization EI (- 0.0001 mean difference (0% change), p = 0.92), or body fat mass (BFM) (+ 0.035 mean difference (0.2% change), p = 0.81). This study suggests that BIA, and more specifically EI, can noninvasively provide valuable information about hemodynamic data. BIA provides a quick, easy, non-invasive method for assessing and managing the volume status in individuals with congenital heart disease.

Pediatric CardiologyVol. 47(2)
Cincinnati Children's Hospital Medical Center (US), Oklahoma Heart Institute (US), Adult Congenital Heart Association (US), Ohio Heart & Vascular Center (US), University of Cincinnati Medical Center (US)
Cincinnati Children's Hospital Medical Center
Openalex Percentile: Top 92%
Body Composition Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.