Performance Evaluation of the Verily Numetric Watch Sleep Suite for Digital Sleep Assessment Against In‐Lab Polysomnography

The goal was to evaluate the performance of a suite of 12 sleep measures generated by a multi-sensor wrist-worn wearable device, the verily numetric watch (VNW), in a diverse cohort. We used polysomnography (PSG) as reference during one-night simultaneous recording in a sample of N = 41 (18 male, age range: 18-78 years). We performed epoch-by-epoch comparisons for all measures. Key specific analyses were: core accuracy metrics for sleep versus wake classification; bias for continuous measures (Bland-Altman); unweighted Cohen's kappa and accuracy for sleep stage classifications and mean count difference and linearly weighted Cohen's kappa for count metric. In addition, we performed exploratory subgroup analyses by sex, age, skin tone, body mass index and arm hair density. Sensitivity and specificity (95% CI) of sleep versus wake classification were 0.97 (0.96, 0.98) and 0.66 (0.61, 0.71), respectively. Mean total sleep time bias was 14.55 min (1.61, 27.16); wake after sleep onset, -11.77 min (-23.89, 1.09); sleep efficiency, 3.15% (0.68, 5.57); sleep onset latency, -3.24 min (-9.38, 3.57); light-sleep duration, 3.78 min (-7.04, 15.06); deep-sleep duration, 3.91 min (-4.59, 12.60) and rapid eye movement-sleep duration, 6.94 min (0.57, 13.04). Mean difference for the number of awakenings, 0.17: (95% CI: -0.32, 0.71) and overall accuracy of sleep stage classification, 0.78 (0.51, 0.88). Most measures showed statistically significant proportional biases and/or heteroscedasticity. Exploratory subgroup results appeared largely consistent with the overall group, although small samples precluded strong conclusions. These results support the use of VNWs in classifying sleep versus wake, sleep stages and overnight sleep measures.

Authors

Institutions

Publication Details

Journal
Journal of Sleep Research
Published
2025-04-01
DOI
https://doi.org/10.1111/jsr.70036
Primary Topic
Sleep and related disorders
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Evaluation of the Verily Numetric Watch Sleep Suite for Digital Sleep Assessment Against In‐Lab Polysomnography

Shannon Sullivan, Fiona C. Baker, Niranjan Sridhar, Poulami Barman et al.
Journal of Sleep Research
Sleep and related disorders
article

Performance Evaluation of the Verily Numetric Watch Sleep Suite for Digital Sleep Assessment Against In‐Lab Polysomnography

Shannon Sullivan, Fiona C. Baker, Niranjan Sridhar, Poulami Barman, Hannah Allen, Nicole Arra, Erin Rainaldi, Sohrab Saeb, Massimiliano de Zambotti, Sooyoon Shin, Nishant Verma, R. Scooter Plowman, Ritu Kapur, Benjamin W. Nelson
article en

Abstract

The goal was to evaluate the performance of a suite of 12 sleep measures generated by a multi-sensor wrist-worn wearable device, the verily numetric watch (VNW), in a diverse cohort. We used polysomnography (PSG) as reference during one-night simultaneous recording in a sample of N = 41 (18 male, age range: 18-78 years). We performed epoch-by-epoch comparisons for all measures. Key specific analyses were: core accuracy metrics for sleep versus wake classification; bias for continuous measures (Bland-Altman); unweighted Cohen's kappa and accuracy for sleep stage classifications and mean count difference and linearly weighted Cohen's kappa for count metric. In addition, we performed exploratory subgroup analyses by sex, age, skin tone, body mass index and arm hair density. Sensitivity and specificity (95% CI) of sleep versus wake classification were 0.97 (0.96, 0.98) and 0.66 (0.61, 0.71), respectively. Mean total sleep time bias was 14.55 min (1.61, 27.16); wake after sleep onset, -11.77 min (-23.89, 1.09); sleep efficiency, 3.15% (0.68, 5.57); sleep onset latency, -3.24 min (-9.38, 3.57); light-sleep duration, 3.78 min (-7.04, 15.06); deep-sleep duration, 3.91 min (-4.59, 12.60) and rapid eye movement-sleep duration, 6.94 min (0.57, 13.04). Mean difference for the number of awakenings, 0.17: (95% CI: -0.32, 0.71) and overall accuracy of sleep stage classification, 0.78 (0.51, 0.88). Most measures showed statistically significant proportional biases and/or heteroscedasticity. Exploratory subgroup results appeared largely consistent with the overall group, although small samples precluded strong conclusions. These results support the use of VNWs in classifying sleep versus wake, sleep stages and overnight sleep measures.

Journal of Sleep ResearchVol. 34(5)
SRI International (US), Beth Israel Deaconess Medical Center (US), Harvard University (US), Radboud University Nijmegen (NL), Radboud University Medical Center (NL), Enzo Life Sciences (United States) (US), Oklahoma State University Center for Health Sciences (US), Stanford University (US)
Verily Life Sciences
Openalex Percentile: Top 94%
Sleep and related disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.