Analytical Modeling and Validation of Radial Stiffness in Zigzag‐Shaped Stents: Experimental and Numerical Approaches

Stents and stent grafts (SGs) are used in many endovascular procedures. Clinical studies have revealed that radial stiffness (RS) in stents increases pressure on the artery wall, which can cause restenosis and, in some cases, require repeated intervention. This study aimed to validate an analytical model for calculating the RS of stents and SG with a zigzag-shaped structure. Four commercial SGs with varying geometric dimensions and material properties were selected. The analytical model's RS calculations were compared with experimental measurements and numerical model predictions. An excellent agreement was observed between the RS values measured in the experimental system and those calculated in the analytical model, with an average difference of 2.4% ± 3.3%. Validation of the analytical model enables the design of stents with a desired RS that is optimally suited to a specific patient.

Authors

Institutions

Publication Details

Journal
Journal of Biomedical Materials Research Part B Applied Biomaterials
Published
2025-04-01
DOI
https://doi.org/10.1002/jbm.b.35574
Citations
2
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
4.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analytical Modeling and Validation of Radial Stiffness in Zigzag‐Shaped Stents: Experimental and Numerical Approaches

Nataly Zilberman Sharon, Moshe Brand
2 citations
Journal of Biomedical Materials Research Part B Applied Biomaterials
Coronary Interventions and Diagnostics
4.01
article

Analytical Modeling and Validation of Radial Stiffness in Zigzag‐Shaped Stents: Experimental and Numerical Approaches

Nataly Zilberman Sharon, Moshe Brand
article en
2 citations

Abstract

Stents and stent grafts (SGs) are used in many endovascular procedures. Clinical studies have revealed that radial stiffness (RS) in stents increases pressure on the artery wall, which can cause restenosis and, in some cases, require repeated intervention. This study aimed to validate an analytical model for calculating the RS of stents and SG with a zigzag-shaped structure. Four commercial SGs with varying geometric dimensions and material properties were selected. The analytical model's RS calculations were compared with experimental measurements and numerical model predictions. An excellent agreement was observed between the RS values measured in the experimental system and those calculated in the analytical model, with an average difference of 2.4% ± 3.3%. Validation of the analytical model enables the design of stents with a desired RS that is optimally suited to a specific patient.

Journal of Biomedical Materials Research Part B Applied BiomaterialsVol. 113(4)
Tel Aviv University (IL), Ariel University (IL)
Openalex Percentile: Top 8%
Coronary Interventions and Diagnostics
4.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.