Impact of Water Mass Flow Rate and Refrigerant Inlet Temperature on LMTD and Heat Transfer in Shell-and-Tube Heat Exchangers for Heat Pumps Using R407C

This paper presents an experimental investigation into the heat transfer performance of a shelland-tube heat exchanger using refrigerant R407C. The study focuses on the Log Mean Temperature Difference (LMTD) and heat transfer rate at varying mass flow rates and refrigerant temperatures. The results show that the rate of heat transfer increases as the mass flow rate increases, with a range of 8.78 kW to 10.72 kW as the mass flow rate changes from 0.08 kg/s to 0.1 kg/s. The increase in heat transfer rate is between 13.6% to 17.8%, with the highest observed at 82°C. The LMTD also increases with rising refrigerant temperature, ranging from 22.98°C to 26.87°C, with the highest value recorded at 84°C. These findings highlight the relationship between mass flow rate, refrigerant temperature, and heat transfer efficiency, offering valuable insights for optimizing heat pump system performance.

Authors

Publication Details

Journal
International Research Journal of Innovations in Engineering and Technology
Published
2025-01-01
DOI
https://doi.org/10.47001/irjiet/2025.903022
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Water Mass Flow Rate and Refrigerant Inlet Temperature on LMTD and Heat Transfer in Shell-and-Tube Heat Exchangers for Heat Pumps Using R407C

R. Chandrashekar, H. B. Bhaskar, N. Lohith, Subodh Kumar
International Research Journal of Innovations in Engineering and Technology
Heat Transfer and Optimization
article

Impact of Water Mass Flow Rate and Refrigerant Inlet Temperature on LMTD and Heat Transfer in Shell-and-Tube Heat Exchangers for Heat Pumps Using R407C

R. Chandrashekar, H. B. Bhaskar, N. Lohith, Subodh Kumar
article en

Abstract

This paper presents an experimental investigation into the heat transfer performance of a shelland-tube heat exchanger using refrigerant R407C. The study focuses on the Log Mean Temperature Difference (LMTD) and heat transfer rate at varying mass flow rates and refrigerant temperatures. The results show that the rate of heat transfer increases as the mass flow rate increases, with a range of 8.78 kW to 10.72 kW as the mass flow rate changes from 0.08 kg/s to 0.1 kg/s. The increase in heat transfer rate is between 13.6% to 17.8%, with the highest observed at 82°C. The LMTD also increases with rising refrigerant temperature, ranging from 22.98°C to 26.87°C, with the highest value recorded at 84°C. These findings highlight the relationship between mass flow rate, refrigerant temperature, and heat transfer efficiency, offering valuable insights for optimizing heat pump system performance.

International Research Journal of Innovations in Engineering and TechnologyVol. 09(03)
Openalex Percentile: Top 94%
Heat Transfer and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Impact of Water Mass Flow Rate and Refrigerant Inlet Temperature on LMTD and Heat Transfer in Shell-and-Tube Heat Exchangers for Heat Pumps Using R407C — R. Chandrashekar, H. B. Bhaskar, et al. · International Research Journal of Innovations in Engineering and Technology (2025) | TGRS Research Map | TGRS