Analytical Quality by Design Assisted Optimization of RP-HPLC Method for the Estimation of Palovarotene Drug Substance and Drug Product by Box–Behnken Design

ABSTRACT: A QbD approach, with its emphasis on risk assessment and management, may result in the establishment of a more robust or rugged system. Critical quality attributes (CQAs) and the analytical target profile were evaluated by closely examining the detailed process for analytical QbD-based optimization parameters. RP- HPLC is considered more useful than normal phase HPLC method since it is more versatile in separating a wider range of compounds, due to its non-polar stationary phase and polar mobile phase, allowing for better control over Rt and mobile phase composition, with improved reproducibility and accuracy compared to normal phase HPLC. The current study outlines the invention and validation of the straightforward, quick, sensitive, and affordable RP-HPLC approach for investigating palovarotene in tablet formulations. Three essential elements of the RP-HPLC approach buffer pH, flow rate and ratio of MP were used in the Box-Behnken design factor screening investigations. The DOE trial version 12.0 was used to optimize the chromatographic settings. With water Platisil C18-EP (4.6 x 250 mm, 5µm) column and comprising of a mobile phase KH2PO4 (pH 3.5): ACN (50:50 ml) v/v, a 1.0 ml/min flow rate and UV range at 261 nm, the best chromatographic separation was accomplished. The interrelationships between MP, pH, and flow rate at 3 distinct levels are described by the Box–Behnken experimental design. RSM plots and statistical data were used to evaluate the retention duration and theoretical plate responses. The current RP-HPLC method for palovarotene was in compliance with the suggested ICH recommendations. The technique can also be utilized for quality control and laboratories evaluation aimed at the assessment of Palovarotene in the drug material and capsule formulation.

Authors

Institutions

Publication Details

Journal
Biosciences Biotechnology Research Asia
Published
2025-03-25
DOI
https://doi.org/10.13005/bbra/3363
Citations
1
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.76
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analytical Quality by Design Assisted Optimization of RP-HPLC Method for the Estimation of Palovarotene Drug Substance and Drug Product by Box–Behnken Design

Chandrasekar Raju, Sivagami Bojan, Chandramouli Chinthaginjala, Meena Dravidamani et al.
1 citations
Biosciences Biotechnology Research Asia
Analytical Chemistry and Chromatography
0.76
article

Analytical Quality by Design Assisted Optimization of RP-HPLC Method for the Estimation of Palovarotene Drug Substance and Drug Product by Box–Behnken Design

Chandrasekar Raju, Sivagami Bojan, Chandramouli Chinthaginjala, Meena Dravidamani, Aruna Kumari Dommaraju, Kumanan Raghunathan
article en
1 citations

Abstract

ABSTRACT: A QbD approach, with its emphasis on risk assessment and management, may result in the establishment of a more robust or rugged system. Critical quality attributes (CQAs) and the analytical target profile were evaluated by closely examining the detailed process for analytical QbD-based optimization parameters. RP- HPLC is considered more useful than normal phase HPLC method since it is more versatile in separating a wider range of compounds, due to its non-polar stationary phase and polar mobile phase, allowing for better control over Rt and mobile phase composition, with improved reproducibility and accuracy compared to normal phase HPLC. The current study outlines the invention and validation of the straightforward, quick, sensitive, and affordable RP-HPLC approach for investigating palovarotene in tablet formulations. Three essential elements of the RP-HPLC approach buffer pH, flow rate and ratio of MP were used in the Box-Behnken design factor screening investigations. The DOE trial version 12.0 was used to optimize the chromatographic settings. With water Platisil C18-EP (4.6 x 250 mm, 5µm) column and comprising of a mobile phase KH2PO4 (pH 3.5): ACN (50:50 ml) v/v, a 1.0 ml/min flow rate and UV range at 261 nm, the best chromatographic separation was accomplished. The interrelationships between MP, pH, and flow rate at 3 distinct levels are described by the Box–Behnken experimental design. RSM plots and statistical data were used to evaluate the retention duration and theoretical plate responses. The current RP-HPLC method for palovarotene was in compliance with the suggested ICH recommendations. The technique can also be utilized for quality control and laboratories evaluation aimed at the assessment of Palovarotene in the drug material and capsule formulation.

Biosciences Biotechnology Research AsiaVol. 22(1)
Almas Hospital (IN), Sri Venkateswara Veterinary University (IN), Hindu College of Pharmacy (IN)
Openalex Percentile: Top 33%
Analytical Chemistry and Chromatography
0.76
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.