A spectrophotometric method was developed for the precise estimation of clonidine hydrochloride (C-HCl) in pure form and pharmaceutical formulations. This method utilizes an ion-pair interaction with 1,2-naphthoquinone-4-sulphonic acid (NQS) in a basic medium (pH 13) at 55°C, producing a peach-colored solution with maximum absorbance at 475 nm. The method demonstrated linearity over 25-225 μg/mL with a molar absorptivity of 2162 L·mol-¹·cm-¹ (R² = 0.9986) and LOD and LOQ values of 6.28 and 19.02 μg/mL, respectively. The average recovery ranged from 96.4% to 101.4%. Kinetic studies indicated pseudo-firstorder kinetics, while thermodynamic analysis using Eyring and Arrhenius equations revealed the reaction to be endothermic and non-spontaneous. The method proved accurate and suitable for C-HCl analysis in pharmaceutical samples.

Authors

Publication Details

Journal
METHODS AND OBJECTS OF CHEMICAL ANALYSIS
Published
2025-01-01
DOI
https://doi.org/10.17721/moca.2025.39-45
Citations
1
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.76
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of ICP-MS Analysis for Studying Matrix Effects in Biological Fluids

Nouroozzadeh Jafar, T. K. Nurubeyli, Kh. N. Ahmadova
1 citations
METHODS AND OBJECTS OF CHEMICAL ANALYSIS
Mass Spectrometry Techniques and Applications
0.76
article

Optimization of ICP-MS Analysis for Studying Matrix Effects in Biological Fluids

Nouroozzadeh Jafar, T. K. Nurubeyli, Kh. N. Ahmadova
article en
1 citations

Abstract

A spectrophotometric method was developed for the precise estimation of clonidine hydrochloride (C-HCl) in pure form and pharmaceutical formulations. This method utilizes an ion-pair interaction with 1,2-naphthoquinone-4-sulphonic acid (NQS) in a basic medium (pH 13) at 55°C, producing a peach-colored solution with maximum absorbance at 475 nm. The method demonstrated linearity over 25-225 μg/mL with a molar absorptivity of 2162 L·mol-¹·cm-¹ (R² = 0.9986) and LOD and LOQ values of 6.28 and 19.02 μg/mL, respectively. The average recovery ranged from 96.4% to 101.4%. Kinetic studies indicated pseudo-firstorder kinetics, while thermodynamic analysis using Eyring and Arrhenius equations revealed the reaction to be endothermic and non-spontaneous. The method proved accurate and suitable for C-HCl analysis in pharmaceutical samples.

METHODS AND OBJECTS OF CHEMICAL ANALYSISVol. 20(1)
Openalex Percentile: Top 33%
Mass Spectrometry Techniques and Applications
0.76
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.