IMPROVEMENTS IN ELECTROCARDIOGRAPHY SMOOTHENING AND AMPLIFICATION

The electrocardiogram (ECG or EKG) is a graphic recording of the time-variant voltages produced by the myocardium during the cardiac cycle.The P, QRS, and T waves reflect the rhythmic electrical depolarization and re-polarization of the myocardium associated with the contractions of the atria and ventricles.The electrocardiogram is generally used clinically in diagnosing diseases of the heart.Hence, it must be very accurate.The ECG waveform is a periodic signal with bandwidth of 0.05 Hz to 100 Hz.Amplitude is typically 1 milli-volt peak to peak in the presence of much larger (1000 times larger) external high frequency noise plus 50/60 Hz interference common mode voltages (common to all electrode signals).We present a method to eliminate much of the noise using a pre-amplifier design with high common mode rejection ratio and high input impedance.We verify our results using computer simulation of the signal via the software MULTISIM 9.0.

Authors

Institutions

Publication Details

Published
2025-04-02
DOI
https://doi.org/10.18260/1-2-1153-53716
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

IMPROVEMENTS IN ELECTROCARDIOGRAPHY SMOOTHENING AND AMPLIFICATION

Sarosh Patel, Lawrence V. Hmurcik, Manan Joshi
ECG Monitoring and Analysis
article

IMPROVEMENTS IN ELECTROCARDIOGRAPHY SMOOTHENING AND AMPLIFICATION

Sarosh Patel, Lawrence V. Hmurcik, Manan Joshi
article en

Abstract

The electrocardiogram (ECG or EKG) is a graphic recording of the time-variant voltages produced by the myocardium during the cardiac cycle.The P, QRS, and T waves reflect the rhythmic electrical depolarization and re-polarization of the myocardium associated with the contractions of the atria and ventricles.The electrocardiogram is generally used clinically in diagnosing diseases of the heart.Hence, it must be very accurate.The ECG waveform is a periodic signal with bandwidth of 0.05 Hz to 100 Hz.Amplitude is typically 1 milli-volt peak to peak in the presence of much larger (1000 times larger) external high frequency noise plus 50/60 Hz interference common mode voltages (common to all electrode signals).We present a method to eliminate much of the noise using a pre-amplifier design with high common mode rejection ratio and high input impedance.We verify our results using computer simulation of the signal via the software MULTISIM 9.0.

University of Bridgeport (US)
Openalex Percentile: Top 88%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.