Transcatheter Aortic Valve Replacement With a Fully Retrievable Self-Expanding Dry-Tissue Valve: First-in-Man Study

Contemporary self-expanding transcatheter aortic valve replacement (TAVR) devices are retrievable and repositionable at partial release, however, valve migration may occur during final release. The Venus-PowerX Valve is a novel self-expanding dry-tissue TAVR device which is retrievable at 100% full deployment. This first-in-man study sought to evaluate the feasibility and safety of the new TAVR device. The clinical outcomes and adverse events were assessed and reported according to the Valve Academic Research Consortium-3 criteria. A total of 25 patients with severe aortic stenosis (75.3 ± 5.3 years, 48.0% male, 52.0% bicuspid aortic valve) were enrolled. Acute technical success was achieved in 25 (100%) patients. Valve recapture at 100% full deployment was attempted in 2 patients due to suboptimal position or inappropriate valve size, and was successful in both. No patient required a second valve. At 30 days, device success was achieved in 88.0%. The reasons for unachieved device success included residual gradient (4.0%), moderate paravalvular leak (PVL, 4.0%) and VARC type 2 bleeding (4.0%). New permanent pacemaker was required in 5 (20.0%) patients. At 1-year follow-up, overall survival rate was 96.0%, there was no stroke, myocardial infarction, or cardiovascular rehospitalization. Mean aortic valve gradient improved significantly from 56.0 ± 17.9 mmHg to 11.6 ± 6.0 mmHg, and effective orifice area improved from 0.6 ± 0.2 cm<sup>2</sup> to 1.8 ± 0.4 cm<sup>2</sup>; 79.1% had none or trivial PVL. In conclusion, the novel fully retrievable Venus-PowerX Valve could enable highly predictable TAVR device positioning and produce satisfactory hemodynamic and clinical outcomes in both bicuspid and tricuspid aortic valve stenosis.

Authors

Institutions

Publication Details

Journal
The American Journal of Cardiology
Published
2025-04-02
DOI
https://doi.org/10.1016/j.amjcard.2025.03.032
Citations
1
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
1.39

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transcatheter Aortic Valve Replacement With a Fully Retrievable Self-Expanding Dry-Tissue Valve: First-in-Man Study

Zhen‐Gang Zhao, Esteban Villegas-Arbeláez, Jorge Baccaro, Xin Wei et al.
1 citations
The American Journal of Cardiology
Cardiac Valve Diseases and Treatments
1.39
article

Transcatheter Aortic Valve Replacement With a Fully Retrievable Self-Expanding Dry-Tissue Valve: First-in-Man Study

Zhen‐Gang Zhao, Esteban Villegas-Arbeláez, Jorge Baccaro, Xin Wei, Scott Lim, Adolfo Lopez Campanher, Zhongkai Zhu, Fei Chen, Xi Li, Mao Chen, Yuan Feng, Yong Peng, Jiafu Wei
article en
1 citations

Abstract

Contemporary self-expanding transcatheter aortic valve replacement (TAVR) devices are retrievable and repositionable at partial release, however, valve migration may occur during final release. The Venus-PowerX Valve is a novel self-expanding dry-tissue TAVR device which is retrievable at 100% full deployment. This first-in-man study sought to evaluate the feasibility and safety of the new TAVR device. The clinical outcomes and adverse events were assessed and reported according to the Valve Academic Research Consortium-3 criteria. A total of 25 patients with severe aortic stenosis (75.3 ± 5.3 years, 48.0% male, 52.0% bicuspid aortic valve) were enrolled. Acute technical success was achieved in 25 (100%) patients. Valve recapture at 100% full deployment was attempted in 2 patients due to suboptimal position or inappropriate valve size, and was successful in both. No patient required a second valve. At 30 days, device success was achieved in 88.0%. The reasons for unachieved device success included residual gradient (4.0%), moderate paravalvular leak (PVL, 4.0%) and VARC type 2 bleeding (4.0%). New permanent pacemaker was required in 5 (20.0%) patients. At 1-year follow-up, overall survival rate was 96.0%, there was no stroke, myocardial infarction, or cardiovascular rehospitalization. Mean aortic valve gradient improved significantly from 56.0 ± 17.9 mmHg to 11.6 ± 6.0 mmHg, and effective orifice area improved from 0.6 ± 0.2 cm<sup>2</sup> to 1.8 ± 0.4 cm<sup>2</sup>; 79.1% had none or trivial PVL. In conclusion, the novel fully retrievable Venus-PowerX Valve could enable highly predictable TAVR device positioning and produce satisfactory hemodynamic and clinical outcomes in both bicuspid and tricuspid aortic valve stenosis.

The American Journal of CardiologyVol. 247
Sichuan University (CN), West China Hospital of Sichuan University (CN), Centro Científico Tecnológico - Nordeste (AR), University of Virginia (US)
National Natural Science Foundation of China, Sichuan University, West China Hospital, Sichuan University
Zero hunger
Openalex Percentile: Top 21%
Cardiac Valve Diseases and Treatments
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.