Non-Invasive Measurement of Hemodynamic Parameters via Whole-Body Impedance Cardiography Among Hospitalized Heart Failure Patients: An Effective Alternative to Invasive Right Heart Catheterization?

(1) Background: The measurement of hemodynamic parameters has proven to be crucial in the treatment of hospitalized heart failure patients, necessitating invasive measurement by right heart catheterization (RHC). The reliability of whole-body impedance cardiography (ICG) among this cohort has not been investigated to date; (2) Methods: The RHC and whole-body ICG examinations measured cardiac output (CO), the cardiac index (CI), total peripheral resistance (TPR), and pulmonary vascular resistance (PVR). To assess the accuracy of the whole-body ICG measurement, bias and precision were calculated as the mean difference and the twofold standard deviation between the average values of measurements; (3) Results: A total of 203 patients were analyzed. No significant bias was observed between the non-invasive CO and CI measurements when compared with the RHC measurements (-0.14 ± 2.56 L/min, <i>p</i> = 0.1; -0.09 ± 1.3 L/min/m<sup>2</sup>, <i>p</i> = 0.06), but a significant bias occurred in the measurement of non-invasive TPR and non-invasive PVR (-1243 ± 3510 dyn × s<sup>-1</sup> × cm<sup>-5</sup>, <i>p</i> = 0.001; -121 ± 504 dyn × s<sup>-1</sup> × cm<sup>-5</sup>, <i>p</i> < 0.001); (4) Conclusions: CO and CI can be measured with whole-body ICG among hospitalized CHF patients with acceptable accuracy. The reliability of measuring TPR and PVR should be further investigated.

Authors

Institutions

Publication Details

Journal
Journal of Cardiovascular Development and Disease
Published
2025-04-02
DOI
https://doi.org/10.3390/jcdd12040128
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-Invasive Measurement of Hemodynamic Parameters via Whole-Body Impedance Cardiography Among Hospitalized Heart Failure Patients: An Effective Alternative to Invasive Right Heart Catheterization?

Felix Ausbuettel, Martina B. Hautmann, Karin Nentwich, Sebastian Kerber et al.
Journal of Cardiovascular Development and Disease
Hemodynamic Monitoring and Therapy
article

Non-Invasive Measurement of Hemodynamic Parameters via Whole-Body Impedance Cardiography Among Hospitalized Heart Failure Patients: An Effective Alternative to Invasive Right Heart Catheterization?

Felix Ausbuettel, Martina B. Hautmann, Karin Nentwich, Sebastian Kerber, Sebastian Barth, Mustafa Abdo, Sabah Khwamurad
article en

Abstract

(1) Background: The measurement of hemodynamic parameters has proven to be crucial in the treatment of hospitalized heart failure patients, necessitating invasive measurement by right heart catheterization (RHC). The reliability of whole-body impedance cardiography (ICG) among this cohort has not been investigated to date; (2) Methods: The RHC and whole-body ICG examinations measured cardiac output (CO), the cardiac index (CI), total peripheral resistance (TPR), and pulmonary vascular resistance (PVR). To assess the accuracy of the whole-body ICG measurement, bias and precision were calculated as the mean difference and the twofold standard deviation between the average values of measurements; (3) Results: A total of 203 patients were analyzed. No significant bias was observed between the non-invasive CO and CI measurements when compared with the RHC measurements (-0.14 ± 2.56 L/min, <i>p</i> = 0.1; -0.09 ± 1.3 L/min/m<sup>2</sup>, <i>p</i> = 0.06), but a significant bias occurred in the measurement of non-invasive TPR and non-invasive PVR (-1243 ± 3510 dyn × s<sup>-1</sup> × cm<sup>-5</sup>, <i>p</i> = 0.001; -121 ± 504 dyn × s<sup>-1</sup> × cm<sup>-5</sup>, <i>p</i> < 0.001); (4) Conclusions: CO and CI can be measured with whole-body ICG among hospitalized CHF patients with acceptable accuracy. The reliability of measuring TPR and PVR should be further investigated.

Journal of Cardiovascular Development and DiseaseVol. 12(4)
Rhön-Klinikum (DE), Philipps University of Marburg (DE)
Good health and well-being
Openalex Percentile: Top 89%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.