Dynamic retinal blood flow analysis: Heartbeat-correlated artery and vein identification in laser speckle flowgraphy

Laser speckle flowgraphy (LSFG) is a non-invasive technique for evaluating retinal and choroidal blood flow, estimating flow velocity using the mean blur rate (MBR) from speckle pattern changes. An LSFG video consists of 120 time frames over approximately four heartbeats. The traditional analysis tool, total retinal artery and vein analysis (TRAVA), requires manual identification of the optic disc and setting up regions of interest (i.e., placing an annulus grid). This manual process is often tedious and subjective. In this study, we introduce an optimized deep-learning framework (utilizing nnU-Net, version 2.1) using temporal blood flow variations across heartbeats as multichannel inputs to automatically identify retinal arteries and veins in LSFG. For model training, an ophthalmologist manually traced arteries and veins in color fundus photographs, which were then converted into LSFG labels by an LSFG expert. Data from 40 patients with both LSFG and fundus photographs were used: 30 for training and ten for testing. The proposed model achieved Dice coefficients of 0.78 ± 0.06 for arteries and 0.79 ± 0.06 for veins, significantly outperforming the state-of-the-art AutoMorph’s core approach (retrained by the same data), which had Dice coefficients of 0.61 ± 0.16 and 0.63 ± 0.07, respectively (p-values ⪅ 0.01). Our method also yielded significantly higher recall and F1 scores in identifying artery and vein segments at the optic disc compared to TRAVA (p-values ⪅ 0.01). For vessel segment counting and blood flow quantification at the optic disc annulus grid, the proposed method showed no significant differences from manual tracing (p-values ≫ 0.05). Overall, nnU-Net with normalized LSFG time frames as multi-channel inputs can automatically identify arteries and veins without manual intervention. This automated method enables the use of LSFG for larger datasets, potentially increasing its adoption and utility.

Authors

Institutions

Publication Details

Published
2025-04-02
DOI
https://doi.org/10.1117/12.3046777
Primary Topic
Retinal Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic retinal blood flow analysis: Heartbeat-correlated artery and vein identification in laser speckle flowgraphy

Randy H. Kardon, Noor-Us-Sabah Ahmad, Mona K. Garvin, Jui-Kai Wang et al.
Retinal Imaging and Analysis
article

Dynamic retinal blood flow analysis: Heartbeat-correlated artery and vein identification in laser speckle flowgraphy

Randy H. Kardon, Noor-Us-Sabah Ahmad, Mona K. Garvin, Jui-Kai Wang, Edward F. Linton, Noriyoshi Takahashi
article en

Abstract

Laser speckle flowgraphy (LSFG) is a non-invasive technique for evaluating retinal and choroidal blood flow, estimating flow velocity using the mean blur rate (MBR) from speckle pattern changes. An LSFG video consists of 120 time frames over approximately four heartbeats. The traditional analysis tool, total retinal artery and vein analysis (TRAVA), requires manual identification of the optic disc and setting up regions of interest (i.e., placing an annulus grid). This manual process is often tedious and subjective. In this study, we introduce an optimized deep-learning framework (utilizing nnU-Net, version 2.1) using temporal blood flow variations across heartbeats as multichannel inputs to automatically identify retinal arteries and veins in LSFG. For model training, an ophthalmologist manually traced arteries and veins in color fundus photographs, which were then converted into LSFG labels by an LSFG expert. Data from 40 patients with both LSFG and fundus photographs were used: 30 for training and ten for testing. The proposed model achieved Dice coefficients of 0.78 ± 0.06 for arteries and 0.79 ± 0.06 for veins, significantly outperforming the state-of-the-art AutoMorph’s core approach (retrained by the same data), which had Dice coefficients of 0.61 ± 0.16 and 0.63 ± 0.07, respectively (p-values ⪅ 0.01). Our method also yielded significantly higher recall and F1 scores in identifying artery and vein segments at the optic disc compared to TRAVA (p-values ⪅ 0.01). For vessel segment counting and blood flow quantification at the optic disc annulus grid, the proposed method showed no significant differences from manual tracing (p-values ≫ 0.05). Overall, nnU-Net with normalized LSFG time frames as multi-channel inputs can automatically identify arteries and veins without manual intervention. This automated method enables the use of LSFG for larger datasets, potentially increasing its adoption and utility.

University of Iowa (US), Center for Visual Communication (United States) (US), The University of Texas Southwestern Medical Center (US)
Openalex Percentile: Top 90%
Retinal Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.