Analysis of factors influencing contact arc erosion under capacitive inrush currents in high-voltage DC relays

High-voltage DC relays are widely used in electric vehicles. Due to the presence of capacitive elements in the circuit, a large inrush current occurs at the moment of power-on, resulting in arcing between the relay contacts. This process erodes the contact surfaces, adversely affecting the relay’s performance and lifespan. Although improvements such as pre-charged circuits are available, capacitive power-on arc erosion remains common. Therefore, this paper presents a two-dimensional simulation model for high-voltage DC relays, based on magnetohydrodynamics. The model incorporates two arc extinguishing methods: high-voltage arc extinguishing medium and magnetic blowout arc extinction. The simulation model is used to examine the dynamic process of arc erosion and the extent of contact erosion. Subsequently, the study selected eight operating conditions for simulations and experiments, then conducted a correlation analysis between the areas of contact melt pools post-simulation and the areas of contact erosion post-experiment. This confirmed the consistency of trends between the simulation results and experimental outcomes. Based on this, the study analyzes the effects of voltage, current, and capacitance on arc erosion, summarizing the physical processes and principles of arc erosion under different factors, and further examines the mechanisms of these factors from perspectives such as maximum instantaneous power and arc energy. Finally, the results indicate that current has the most significant impact on contact arc erosion. The simulation model has broad applicability and provides practical significance for analyzing arc erosion under capacitive inrush currents in high-voltage DC relays, significantly improving research efficiency.

Authors

Institutions

Publication Details

Journal
AIP Advances
Published
2025-04-01
DOI
https://doi.org/10.1063/5.0255511
Citations
3
Primary Topic
Vacuum and Plasma Arcs
Type
article
Field-Weighted Citation Impact
3.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of factors influencing contact arc erosion under capacitive inrush currents in high-voltage DC relays

Haitao Wang, S. T. Li, Wei Li, Wenli Jiang et al.
3 citations
AIP Advances
Vacuum and Plasma Arcs
3.74
article

Analysis of factors influencing contact arc erosion under capacitive inrush currents in high-voltage DC relays

Haitao Wang, S. T. Li, Wei Li, Wenli Jiang, Zhen Lin, Qinneng Liu
article en
3 citations

Abstract

High-voltage DC relays are widely used in electric vehicles. Due to the presence of capacitive elements in the circuit, a large inrush current occurs at the moment of power-on, resulting in arcing between the relay contacts. This process erodes the contact surfaces, adversely affecting the relay’s performance and lifespan. Although improvements such as pre-charged circuits are available, capacitive power-on arc erosion remains common. Therefore, this paper presents a two-dimensional simulation model for high-voltage DC relays, based on magnetohydrodynamics. The model incorporates two arc extinguishing methods: high-voltage arc extinguishing medium and magnetic blowout arc extinction. The simulation model is used to examine the dynamic process of arc erosion and the extent of contact erosion. Subsequently, the study selected eight operating conditions for simulations and experiments, then conducted a correlation analysis between the areas of contact melt pools post-simulation and the areas of contact erosion post-experiment. This confirmed the consistency of trends between the simulation results and experimental outcomes. Based on this, the study analyzes the effects of voltage, current, and capacitance on arc erosion, summarizing the physical processes and principles of arc erosion under different factors, and further examines the mechanisms of these factors from perspectives such as maximum instantaneous power and arc energy. Finally, the results indicate that current has the most significant impact on contact arc erosion. The simulation model has broad applicability and provides practical significance for analyzing arc erosion under capacitive inrush currents in high-voltage DC relays, significantly improving research efficiency.

AIP AdvancesVol. 15(4)
Hebei University of Technology (CN)
Natural Science Foundation of Hebei Province
Openalex Percentile: Top 8%
Vacuum and Plasma Arcs
3.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.