Research on Insulation Coordination Design for ±600kV Bipolar HVDC Transmission Line with Dedicated Metallic Return in Chile

The paper developed a new insulation coordination design method to create a tower head electrical design, which meets the requirements of environmental conditions for the first ±600kV HVDC Kimal Lo Aguirre (KILO) project in Chile. Based on the results of the overvoltage study, and considering the local Chilean climate and pollution research results, combined with the mature design and operational experience of ±800kV transmission lines in China, specific recommendations were made for the selection of insulators for the pole conductors and Dedicated Metallic Return (DMR). According to the relevant standards such as the current IEC standards, Cigre standards, and Chilean regulations, the electrical clearances for the pole conductors and DMR of the ±600kV HVDC project were calculated. By integrating the recommended insulator types and electrical clearance values, typical tower head electrical design suitable for the ±600kV HVDC transmission project with DMR was developed.

Authors

Institutions

Publication Details

Published
2024-10-19
DOI
https://doi.org/10.1109/dcts62535.2024.10939804
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Insulation Coordination Design for ±600kV Bipolar HVDC Transmission Line with Dedicated Metallic Return in Chile

Jose Miguel Silva, F. Rojas, F. Garcia, Yixin Yu et al.
High voltage insulation and dielectric phenomena
article

Research on Insulation Coordination Design for ±600kV Bipolar HVDC Transmission Line with Dedicated Metallic Return in Chile

Jose Miguel Silva, F. Rojas, F. Garcia, Yixin Yu, Y. B. Gan, Qingming Xin
article en

Abstract

The paper developed a new insulation coordination design method to create a tower head electrical design, which meets the requirements of environmental conditions for the first ±600kV HVDC Kimal Lo Aguirre (KILO) project in Chile. Based on the results of the overvoltage study, and considering the local Chilean climate and pollution research results, combined with the mature design and operational experience of ±800kV transmission lines in China, specific recommendations were made for the selection of insulators for the pole conductors and Dedicated Metallic Return (DMR). According to the relevant standards such as the current IEC standards, Cigre standards, and Chilean regulations, the electrical clearances for the pole conductors and DMR of the ±600kV HVDC project were calculated. By integrating the recommended insulator types and electrical clearance values, typical tower head electrical design suitable for the ±600kV HVDC transmission project with DMR was developed.

Electric Power Research Institute (US), China Southern Power Grid (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 82%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.