LCC-MMC HVDC Line Pilot Protection Based on U-Q Characteristic Curve

Hybrid high-voltage DC systems are gradually becoming the main form of DC engineering. The distributed capacitance effect of long-distance DC lines is very obvious, which leads to the fact that the existing pilot protection schemes need a long enough rectification delay to avoid false operation. This article proposes a pilot protection principle based on U-Q transient characteristics. The U-Q characteristic of the line is a regular linear spiral characteristic under normal operation and external fault (EF) condition. For internal fault (IF), the transient U-Q characteristic of the transmission lines are nonlinear. Based on this difference in characteristics, A pilot protection scheme will be developed on the basis of transient U Q characteristics. The proposed scheme is less computationally intensive and is not constrained by system parameters. The model is constructed in PSCAD/EMTDC and a large number of simulations are carried out to test the speed and stability of the proposed scheme. The simulations under different conditions show that the proposed scheme can act quickly and reliably and has good robustness to high resistance faults.

Authors

Institutions

Publication Details

Published
2024-10-19
DOI
https://doi.org/10.1109/dcts62535.2024.10939351
Citations
2
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

LCC-MMC HVDC Line Pilot Protection Based on U-Q Characteristic Curve

Shaonan Wang, Yi Luo, D.D. Tang, Guangjin Li et al.
2 citations
HVDC Systems and Fault Protection
0.42
article

LCC-MMC HVDC Line Pilot Protection Based on U-Q Characteristic Curve

Shaonan Wang, Yi Luo, D.D. Tang, Guangjin Li, Nuo Chen, Yu Ling
article en
2 citations

Abstract

Hybrid high-voltage DC systems are gradually becoming the main form of DC engineering. The distributed capacitance effect of long-distance DC lines is very obvious, which leads to the fact that the existing pilot protection schemes need a long enough rectification delay to avoid false operation. This article proposes a pilot protection principle based on U-Q transient characteristics. The U-Q characteristic of the line is a regular linear spiral characteristic under normal operation and external fault (EF) condition. For internal fault (IF), the transient U-Q characteristic of the transmission lines are nonlinear. Based on this difference in characteristics, A pilot protection scheme will be developed on the basis of transient U Q characteristics. The proposed scheme is less computationally intensive and is not constrained by system parameters. The model is constructed in PSCAD/EMTDC and a large number of simulations are carried out to test the speed and stability of the proposed scheme. The simulations under different conditions show that the proposed scheme can act quickly and reliably and has good robustness to high resistance faults.

China Southern Power Grid (China) (CN)
Openalex Percentile: Top 35%
HVDC Systems and Fault Protection
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

LCC-MMC HVDC Line Pilot Protection Based on U-Q Characteristic Curve — Shaonan Wang, Yi Luo, et al. · (2024) | TGRS Research Map | TGRS