Microsecond Dynamic Response Calibration of ITO Thin-Film Thermocouples Under Laser and Detonation Conditions

In this work, we designed and built two types of calibration devices to study the dynamic characteristics of the indium tin oxide (ITO) thin-film thermocouples (TFTCs) under different conditions. The first device, based on a nanosecond laser, generates a 150 mW heat pulse within 25 ns, and the experimental analysis of the cooling process reveals the dynamic characteristics of the ITO TFTCs under natural convection conditions. The second device uses a detonation wave that generates a 270 °C airflow environment in 400 ns at 4.86 Mach, representing forced convection conditions. Experimental results show that in the nanosecond laser experiment, the time constant of the ITO TFTC is 122.08 μs, corresponding to a frequency response of 1.30 kHz. In contrast, in the detonation wave experiment, the time constant of the ITO TFTCs decreases to 15.65 μs and the frequency response increase to 10.17 kHz. These results demonstrate that the dynamic characteristics of the ITO TFTCs are not constant and can be significantly influenced by the measurement environment.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-04-03
DOI
https://doi.org/10.1109/jsen.2025.3555430
Citations
4
Primary Topic
Advanced Sensor Technologies Research
Type
article
Field-Weighted Citation Impact
2.70

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microsecond Dynamic Response Calibration of ITO Thin-Film Thermocouples Under Laser and Detonation Conditions

Xinhang Jin, Xingxu Zhang, Jinjun Deng, Binghe Ma
4 citations
IEEE Sensors Journal
Advanced Sensor Technologies Research
2.70
article

Microsecond Dynamic Response Calibration of ITO Thin-Film Thermocouples Under Laser and Detonation Conditions

Xinhang Jin, Xingxu Zhang, Jinjun Deng, Binghe Ma
article en
4 citations

Abstract

In this work, we designed and built two types of calibration devices to study the dynamic characteristics of the indium tin oxide (ITO) thin-film thermocouples (TFTCs) under different conditions. The first device, based on a nanosecond laser, generates a 150 mW heat pulse within 25 ns, and the experimental analysis of the cooling process reveals the dynamic characteristics of the ITO TFTCs under natural convection conditions. The second device uses a detonation wave that generates a 270 °C airflow environment in 400 ns at 4.86 Mach, representing forced convection conditions. Experimental results show that in the nanosecond laser experiment, the time constant of the ITO TFTC is 122.08 μs, corresponding to a frequency response of 1.30 kHz. In contrast, in the detonation wave experiment, the time constant of the ITO TFTCs decreases to 15.65 μs and the frequency response increase to 10.17 kHz. These results demonstrate that the dynamic characteristics of the ITO TFTCs are not constant and can be significantly influenced by the measurement environment.

IEEE Sensors JournalVol. 25(10)
Northwestern Polytechnical University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 11%
Advanced Sensor Technologies Research
2.70
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Microsecond Dynamic Response Calibration of ITO Thin-Film Thermocouples Under Laser and Detonation Conditions — Xinhang Jin, Xingxu Zhang, et al. · IEEE Sensors Journal (2025) | TGRS Research Map | TGRS