Research On The Calculation Of Air Clearance In The Valve Hall Of A Converter Station Under Ultra-High Altitude Conditions

To ensure the reasonable and safe electrical layout for converter stations, appropriate air clearance must be determined. At high altitudes, air clearance design has a significant impact. The g parameter method which is commonly used for adjusting non-standard meteorological conditions, is applicable only when the altitude is below 2000 m. With the development of HVDC technology, many converter stations are located above 2000 m, some even over 4000 m. The national standard GB/T 42001-2022 provides additional altitude correction methods for systems above 2000 m, but detailed analysis is lacking. This paper calibrates air clearance for altitudes of $2880 \mathrm{~m}, 3000 \mathrm{~m}, 4000 \mathrm{~m}$, and 4500 m based on the g parameter method and GB/T 420012022, and compares the differences to provide a reference for high-altitude HVDC converter station design.

Authors

Institutions

Publication Details

Published
2024-10-19
DOI
https://doi.org/10.1109/dcts62535.2024.10939477
Primary Topic
Aerodynamics and Fluid Dynamics Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research On The Calculation Of Air Clearance In The Valve Hall Of A Converter Station Under Ultra-High Altitude Conditions

Jingsong Zhang, Wentao Huang, Yongxia Han, Fengyun Wang et al.
Aerodynamics and Fluid Dynamics Research
article

Research On The Calculation Of Air Clearance In The Valve Hall Of A Converter Station Under Ultra-High Altitude Conditions

Jingsong Zhang, Wentao Huang, Yongxia Han, Fengyun Wang, Jianfeng Shi, Dong Yang
article en

Abstract

To ensure the reasonable and safe electrical layout for converter stations, appropriate air clearance must be determined. At high altitudes, air clearance design has a significant impact. The g parameter method which is commonly used for adjusting non-standard meteorological conditions, is applicable only when the altitude is below 2000 m. With the development of HVDC technology, many converter stations are located above 2000 m, some even over 4000 m. The national standard GB/T 42001-2022 provides additional altitude correction methods for systems above 2000 m, but detailed analysis is lacking. This paper calibrates air clearance for altitudes of $2880 \mathrm{~m}, 3000 \mathrm{~m}, 4000 \mathrm{~m}$, and 4500 m based on the g parameter method and GB/T 420012022, and compares the differences to provide a reference for high-altitude HVDC converter station design.

China Southern Power Grid (China) (CN), South China University of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 53%
Aerodynamics and Fluid Dynamics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.